![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 817](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735817.webp)
Remote Control Commands
R&S
®
SMBV100A
802
Operating Manual 1176.8016.02 ─ 17
Example:
PULM:TRIG:EXT:GATE:POL NORM
The pulse signal is generated while the gate signal is high.
Options:
R&S SMBV-K23 (Pulse Generator)
Manual operation:
See
" Gate Input Polarity - Pulse Generator "
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance
<Impedance>
Selects the impedance for external pulse trigger.
Parameters:
<Impedance>
G50 | G10K
*RST:
G50
Example:
SOUR:PULM:TRIG:EXT:IMP G50
selects 50 Ohm as the trigger impedance for the external pulse
trigger.
Options:
R&S SMBV-K22 (Pulse Modulator)
Manual operation:
See
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe
<Slope>
Sets the polarity of the active slope of an applied trigger at the PULSE EXT connector.
Parameters:
<Slope>
NEGative | POSitive
*RST:
POSitive
Example:
PULM:TRIG:EXT:SLOP NEG
The pulse generator is triggered on the negative slope of the
external trigger signal.
Options:
R&S SMBV-K23 (Pulse Generator)
Manual operation:
See
" External Trigger Input Slope - Pulse Generator "
[:SOURce<hw>]:PULM:TRIGger:MODE
<Mode>
Selects the trigger mode for pulse modulation.
SOURce Subsystem