![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 331](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735331.webp)
Instrument Function
R&S
®
SMBV100A
316
Operating Manual 1176.8016.02 ─ 17
The digitally modulated signal can either be output directly or converted to an analog
I/Q baseband output signal. The
analog baseband signal
can be output single-ended
or differential (non-inverted).
The analog signal is output at the I/Q output connectors I OUT/I OUT BAR and Q OUT/
Q OUT BAR on the rear panel of the instrument.
Equipped with option R&S
SMBV-K18, Digital Baseband Connectivity, the instrument
also provides the output of the digital I/Q signal, indicated in the "BB In/Out" function
block. Refer to
Chapter 5.8, "Digital I/Q Output Settings"
on page 320 for description.
5.7.3.1
I/Q Out Settings Menu
The settings dialogs for the analog signal output are available in the block diagram in
the "AWGN/IMP" function block as well as in the menu with the same name which is
opened using the MENU key.
Selecting the menu item "I/Q Out Settings" opens a dialog with the parameters for the
I/Q output signal.
The settings dialog for output of the digital signal is accessed in the "BB In/Out" func-
tion block, see
Chapter 5.8, "Digital I/Q Output Settings"
5.7.3.2
Analog I/Q Output
The differential output of the R&S
SMBV provides symmetrical signals for differential
inputs of DUTs without the need of additional external electric network.
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block
Содержание SMBV100A
Страница 1: ...R S SMBV100A Vector Signal Generator Operating Manual Operating Manual 1176 8016 02 17 ÚÞ 2 ...
Страница 31: ...Contents R S SMBV100A 16 Operating Manual 1176 8016 02 17 ...
Страница 129: ...Manual Operation R S SMBV100A 114 Operating Manual 1176 8016 02 17 Legend of Front Panel Controls ...