![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 407](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735407.webp)
Instrument Function
R&S
®
SMBV100A
392
Operating Manual 1176.8016.02 ─ 17
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce
Sync. Output to External Trigger
(enabled for "Trigger Source > External")
Enables/disables output of the signal synchronous to the external trigger event.
For R&S SMBV instruments:
For or two or more R&S SMBVs configured to work in a master-slave mode for syn-
chronous signal generation, configure this parameter depending on the provided sys-
tem trigger event and the properties of the output signal. See
view of the required settings.
Table 5-11: Typical Applications
System Trigger
Application
"Sync. Output to External Trig-
ger"
Common External Trigger event
for the master and the slave
instruments
All instruments are synchronous
to the external trigger event
ON
All instruments are synchronous
among themselves but starting
the signal from first symbol is
more important than synchronicity
with external trigger event
OFF
Internal trigger signal of the mas-
ter R&S SMBV for the slave
instruments
All instruments are synchronous
among themselves
OFF
"On"
Corresponds to the default state of this parameter.
The signal calculation starts simultaneously with the external trigger
event but because of the instrument’s processing time the first sam-
ples are cut off and no signal is outputted. After elapsing of the inter-
nal processing time, the output signal is synchronous to the trigger
event.
Baseband Signal - Baseband Block
Содержание SMBV100A
Страница 1: ...R S SMBV100A Vector Signal Generator Operating Manual Operating Manual 1176 8016 02 17 ÚÞ 2 ...
Страница 31: ...Contents R S SMBV100A 16 Operating Manual 1176 8016 02 17 ...
Страница 129: ...Manual Operation R S SMBV100A 114 Operating Manual 1176 8016 02 17 Legend of Front Panel Controls ...