Remote Control Commands
R&S
®
SMBV100A
651
Operating Manual 1176.8016.02 ─ 17
After selection, modulation parameters "Modulation Type" (
:BB:DM:FORMat
), "Symbol
Rate" (
:BB:DM:SRATe
), "Filter" (
:BB:DM:FILTer:TYPE
and
:BB:DM:FILTer:PARameter:...
) and "Coding" (
:BB:DM:CODing
) are auto-
matically set in accordance with the standard.
The
USER
parameter cannot be set. A query returns this value if a user-defined Cus-
tom Dig Mod setting was loaded or if one of the associated settings was changed sub-
sequent to the selection of a standard. The user defined settings are stored and loaded
with commands
:BB:DM:STAN:ULIS:...
Parameters:
<Standard>
USER | BLUetooth | DECT | ETC | GSM | GSMEdge | NADC |
PDC | PHS | TETRa | W3GPp | TDSCdma | CFORward |
CREVerse | WORLdspace | TFTS | APCOPH1C4fm |
APCOPH1CQpsk | APCOPH2HCpm | APCOPH2HDQpsk |
APCOPH2HD8PSKW | APCOPH2HD8PSKN | APCOPH1Lsm |
APCOPH1Wcqpsk
*RST:
GSM
Example:
BB:DM:STAN DECT
Selects digital modulation according to the DECT standard.
Manual operation:
See
[:SOURce<hw>]:BB:DM:STATe
<State>
Enables/disables digital modulation. Switching on digital modulation turns off all the
other digital standards in the same signal path.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOURce1:BB:DM:STATe ON
Manual operation:
See
[:SOURce<hw>]:BB:DM:SWITching:SOURce
<Source>
Selects the source of the CW control signal for switching between a modulated and an
unmodulated signal.
Parameters:
<Source>
INTernal
INTernal
The CW signal in the control list is used for the control.
*RST:
INTernal
Example:
BB:DM:SWIT INT
the CW signal in the control list is used for the control.
Manual operation:
See
SOURce Subsystem
Содержание SMBV100A
Страница 1: ...R S SMBV100A Vector Signal Generator Operating Manual Operating Manual 1176 8016 02 17 ÚÞ 2 ...
Страница 31: ...Contents R S SMBV100A 16 Operating Manual 1176 8016 02 17 ...
Страница 129: ...Manual Operation R S SMBV100A 114 Operating Manual 1176 8016 02 17 Legend of Front Panel Controls ...