![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 687](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735687.webp)
Remote Control Commands
R&S
®
SMBV100A
672
Operating Manual 1176.8016.02 ─ 17
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:DM:PRAM:BBON ON
selects power ramping in the baseband only.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:FDELay
<FDelay>
Sets the delay in the falling edge. A positive value gives rise to a delay and a negative
value causes an advance.
Parameters:
<FDelay>
float
Range:
-4 to 4
Increment: 0.01
*RST:
0
Default unit: symbol
Example:
BB:DM:PRAM:FDEL 1
The falling edge starts 1 symbol later.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:RDELay
<RDelay>
Sets the delay in the rising edge. A positive value gives rise to a delay and a negative
value causes an advance.
Parameters:
<RDelay>
float
Range:
0 to 4
Increment: 0.01
*RST:
0
Default unit: symbol
Example:
BB:DM:PRAM:RDEL 1
The rising edge starts 1 symbol later.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:SHAPe
<Shape>
The command sets the edge shape of the ramp envelope.
Parameters:
<Shape>
LINear | COSine
*RST:
COSine