Instrument Function
R&S
®
SMBV100A
398
Operating Manual 1176.8016.02 ─ 17
"Next Seg-
ment"
Depending on the trigger setting, the segment selected under "Next
Segment" is output either immediately or after a trigger event.
●
In the case of "internal Trigger = Auto", output starts at once and
the segment is generated continuously.
If the segment index is changed in "Next Segment", output of the
current segment is stopped and the new segment is output imme-
diately, following a system-imposed signal gap.
●
In the case of "internal Trigger = Armed_Auto", output starts after
the first trigger event. The segment is then generated continu-
ously.
If the segment index is changed in "Next Segment", output of the
current segment is stopped and the new segment is output imme-
diately, following a system-imposed signal gap.
●
In the case of "internal Trigger = Armed_Retrigger", output starts
after the first trigger event. The segment is then generated contin-
uously.
If the segment index is changed in "Next Segment", signal output
is stopped and the new segment is not output until a trigger
occurs.
●
In the case of "internal Trigger = Single", output starts after the
first trigger event. The segment is then generated once. Further
trigger events cause a restart.
If the segment index is changed in "Next Segment", the new seg-
ment is not output until a trigger occurs.
●
In the case of "External Trigger = Auto", output starts at once and
the segment is generated continuously.
Further trigger events are ignored. Each next segment trigger
event switches over to outputting the subsequent segment, fol-
lowing a system-imposed signal gap.
If the segment index is changed in "Next Segment", output of the
current segment is stopped and the new segment is output imme-
diately, following a system-imposed signal gap.
The subsequent trigger event after the last segment causes the
first segment to be output again.
●
In the case of "External Trigger = Armed_Auto", output starts after
the first trigger event. The segment is then generated continu-
ously.
Further trigger events are ignored. Each next segment trigger
event switches over to outputting the subsequent segment, fol-
lowing a system-imposed signal gap.
If the segment is changed in Next Segment, signal output is stop-
ped and the new segment is not output until a trigger occurs.
The subsequent trigger event after the last segment causes the
first segment to be output again.
●
In the case of "External Trigger = Single", output starts after the
first trigger event. The segment is then generated once.
Each trigger event (re-)starts the segment; each next segment
trigger event switches over to outputting the subsequent segment.
If the segment is changed in "Next Segment", signal output is not
stopped. The new segment is not output until a trigger occurs.