Nellcor SpO2 Sensors
Portable Bedside Capnograph/Pulse Oximeter
59
MAX-FAST
>40 kg
O
XI
M
AX
®
OxiCliq
®
oxygen transducer
(single-use only)
P
10 to 50 kg
A
>30 kg
O
XI
M
AX
®
Dura-Y
®
multisite oxygen transducer
(Nonsterile, reusable)
D-YS
>1 kg
For use with Dura-Y sensor:
Ear clip (Reusable, nonsterile)
Pedi-Check™ pediatric spot-check clip
(Reusable, nonsterile)
D-YSE
30 kg
D-YSPD
3 to 4 kg
O
XI
M
AX
®
Oxiband
®
oxygen transducer
(Reusable with disposable nonsterile
adhesive)
OXI-A/N
<3 kg or>40 kg
OXI-P/I
3 to 40 kg
O
XI
M
AX
®
Durasensor
®
oxygen transducer
(Nonsterile, reusable)
DS-100A
>40 kg
Nellcor™ Preemie SpO
2
Sensor, non-
adhesive (Single-patient use)
SC-PR
<1.5 kg
Nellcor™ Neonatal SpO
2
Sensor, non-
adhesive (Single-patient use)
SC-NEO
1.5 to 5 kg
Nellcor™ Adult SpO
2
Sensor, non-adhesive
(Single-patient use)
SC-A
>40 kg
Nellcor™ Adult Respiratory Sensor, SpO
2
, RR
10068119
>30 kg
Sensor cable DOC-10
DOC-10
NA
Sensor cable OC-3
OC-3
NA
Performance Considerations
WARNING:
Pulse oximetry readings and pulse signal can be affected by certain ambient environmental
conditions, sensor application errors, and patient conditions.
WARNING:
Tissue damage can be caused by incorrect application or inappropriate duration of use of an
SpO
2
sensor. Inspect the sensor site as directed in the sensor
Directions for Use
.
WARNING:
Use only Nellcor-approved sensors and pulse oximetry cables. Other sensors or oximetry
cables may cause improper monitor performance and may also result in increased
electromagnetic emission or decreased immunity to electromagnetic interference
.
Inaccurate measurements can be caused by:
•
incorrect application of the sensor
•
placement of the sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line
•
ambient light
•
prolonged and/or excessive patient movement
•
intravascular dyes or externally applied coloring, such as nail polish or pigmented cream
•
failure to cover the sensor site with opaque material in high ambient light conditions
Loss-of-pulse signal can occur for the following reasons:
•
the sensor is applied too tightly
•
a blood pressure cuff is inflated on the same extremity as the one with the sensor attached
•
there is arterial occlusion proximal to the sensor
Содержание Capnostream 20p
Страница 1: ...Capnostream 20p Portable Bedside Monitor Capnograph Pulse Oximeter Operator s Manual PN 012194C 0482...
Страница 20: ......
Страница 44: ......
Страница 54: ......
Страница 70: ......
Страница 94: ......
Страница 98: ...Printed Report Options 96 Portable Bedside Capnograph Pulse Oximeter Figure 36 Apnea and Desat Printed Report...
Страница 138: ......