Printed Reports
Portable Bedside Capnograph/Pulse Oximeter
99
Report Name
Description
Fields Included
Time Frame of Report
between data entries is
the lowest resolution
available for trend
increment display
(30 seconds).
Patient Readings: Three of the following
parameters (according to parameters
chosen in the PRINT FORMAT screen, see
): EtCO
2
,
FiCO
2
, RR, SpO
2
, PR, IPI.
available
Patient Urgent and Caution Alarm
Occurrences All patient urgent and caution
alarms
Equipment Advisory Message Occurrences
Events: EVENT 1, EVENT 2, EVENT 3
Graphical Case
Report
Patient readings of
recorded case in
graphical format. The
time between data
entries is the lowest
resolution available for
trend increment display
(30 seconds).
Patient Readings at start and end of
recording period: EtCO
2
, RR, SpO
2
, PR,
IPI.
From start of case until
current time; once case is
stopped, data is not
available
Graphs of levels of two of the following
parameters (according to the parameters
chosen in the PRINT FORMAT screen, see
) at 30-second
intervals: EtCO
2
(mmHg), RR (bpm), SpO
2
(%), PR (bpm), IPI.
Tabular Trend
Report
Patient readings of trend
memory in tabular
format. The time
between data entries is
the resolution set for
trend increment display
(MINIMUM [30
seconds], 1.5 minutes,
3 minutes, 15 minutes,
60 minutes).
DATE, TIME
Trend data as appears on
the trend screen which is
currently displayed, or, if
printing from the PRINT
screen, the trend screen
which was most recently
displayed. Only the data
points currently visible on
the screen (approximately
ten data points) will be
printed. Thus, the ZOOM
level on the trend screen
(choices are 2, 4, and 12
hours), will determine the
number of minutes/hours of
data seen in the printout.
Once trend is erased, data
is not available.
Patient Readings at start of recording
period: EtCO
2
, FiCO
2
, RR, SpO
2
, PR, IPI.
Patient readings at intervals set for trend
increment display: Three of the following
parameters (according to parameters
chosen in the PRINT FORMAT screen, see
): EtCO
2
,
FiCO
2
, RR, SpO
2
, PR, IPI.
Patient Urgent and Caution Alarm
Occurrences
Equipment Advisory Message Occurrences
Events: EVENT 1, EVENT 2, EVENT 3
Graphical Trend
Report
Patient readings of trend
memory in graphical
format. The time
between data entries is
the resolution set for
trend increment display
(MINIMUM [30
seconds], 1.5 minutes,
3 minutes, 15 minutes,
60 minutes).
Patient Readings at start of recording
period: EtCO
2
, RR, SpO
2
, PR, IPI.
Graphs of levels of two of the following
parameters (according to the parameters
chosen in the PRINT FORMAT screen, see
) at interval set
for trend increment display: EtCO
2
, RR,
SpO
2
, PR, IPI.
Trend data as appears on
the trend screen which is
currently displayed, or, if
printing from the PRINT
screen, the trend screen
which was most recently
displayed. Thus, the ZOOM
level on the trend screen
(choices are 2, 4, and 12
hours), will determine the
number of hours of data
seen in the printout. Once
trend is erased, data is not
available.
Real Time
Continuous
Waveform
Graphical presentation
of levels of etCO
2
and
SpO
2
, with a data point
every 50 milliseconds
Patient Readings at start of recording
period: EtCO
2
, FiCO
2
, RR, SpO
2
, PR
Graphs of levels of EtCO
2
and SpO
2
.
Real-time data from time
START PRINTER
is
pressed to time
STOP
PRINTER
is pressed
Содержание Capnostream 20p
Страница 1: ...Capnostream 20p Portable Bedside Monitor Capnograph Pulse Oximeter Operator s Manual PN 012194C 0482...
Страница 20: ......
Страница 44: ......
Страница 54: ......
Страница 70: ......
Страница 94: ......
Страница 98: ...Printed Report Options 96 Portable Bedside Capnograph Pulse Oximeter Figure 36 Apnea and Desat Printed Report...
Страница 138: ......