Parameter Tables
5-
85
K
K
K
K
Factory
Settings
that
Change
with
the
Inverter
Capacity
(o2-04)
The
factory settings of the following parameters will change if the Inverter capacity (o2-04) is changed.
n
200-V
Class
Inverters
Parame-
ter
Num-
ber
Name
Unit
Factory Setting
-
Inverter Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
o2-04
kVA selection
-
0
1
2
3
4
5
6
7
8
b8-03
Energy-saving
filter time
constant
s
0.50
(Open loop vector control)
b8-04
Energy-saving
coeffi-
cient
-
288.20
223.70
169.40
156.80
122.90
94.75
72.69
70.44
63.13
C6-02
Carrier
frequency selec-
tion
*
-
6
6
6
6
6
6
6
6
6
-
Carrier
frequency selec-
tion
upper limit
-
6
6
6
6
6
6
6
6
6
E2-01
(E4-01)
Motor
rated current
A
1.90
3.30
6.20
8.50
14.00
19.60
26.60
39.7
53.0
E2-02
(E4-02)
Motor
rated slip
Hz
2.90
2.50
2.60
2.90
2.73
1.50
1.30
1.70
1.60
E2-03
(E4-03)
Motor
no-load current
A
1.20
1.80
2.80
3.00
4.50
5.10
8.00
11.2
15.2
E2-05
(E4-05)
Motor
line-to-line resis-
tance
Ω
9.842
5.156
1.997
1.601
0.771
0.399
0.288
0.230
0.138
E2-06
(E4-06)
Motor
leak inductance
%
18.2
13.8
18.5
18.4
19.6
18.2
15.5
19.5
17.2
E2-10
Motor
iron loss for
torque
compensation
W
14
26
53
77
112
172
262
245
272
L2-02
Momentary
power loss
ridethru
time
s
0.1
0.1
0.2
0.3
0.5
1.0
1.0
1.0
2.0
L2-03
Min.
baseblock (BB)
time
s
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
L2-04
Voltage
recovery time
s
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
L8-02
Overheat
pre-alarm level
°
C
95
95
95
100
95
95
95
95
90