4
-8
L1-01
Motor
protection
selection
Set
to enable or disable the motor overload
protection
function using the electronic ther-
mal
relay.
0:
Disabled
1:
General motor protection
2:
Inverter motor protection
3:
Vector motor protection
0
to 3
1
5-56
6-47
IMPORTANT
When C6-01 is set to 0 (CT), not-low noise will apply and the Inverter overload withstand ratio will be
150% of the Inverter rating per minute. When C6-01 is set to 1 (VT), low noise will apply and the Inverter
overload withstand ratio will be 120% of the Inverter rating per minute. If C6-01 is set to 1 (VT) when
overload withstand capability is required by the application, the life of the Inverter may be reduced.
Table 4.3 Parameters that are set as required
Parame-
ter Num-
ber
Name
Description
Setting Range
Factory
Setting
Page
b1-03
Stopping
method
selection
The
stopping method when the stop com-
mand
is input.
0:
Deceleration to stop
1:
Coast to stop
2:
DC braking stop
3:
Coast to stop with timer
0
to 3
0
5-13
6-14
C6-02
Carrier
frequency
selection
The
carrier frequency is set low if the motor
cable
is 50 m or longer or to reduce radio
noise
or leakage current. The factory setting
and
setting range depends on the setting of
C6-01.
0
to F
Depends
on
setting
of
C6-01.
5-25
d1-01
to
d1-04
and
d1-17
Frequency
refer-
ences
1 to 4 and
jog
frequency ref-
erence
Set
the required speed references for multi-
step
speed operation or jogging.
0
to 400.00 Hz
d1-01
to
d1-04:
0.00
Hz
d1-17:
6.00
Hz
5-27
6-6
H4-02
and
H4-05
FM
and AM termi-
nal
output gain
Adjust
when an instrument is connected to
the
FM or AM terminal.
0.00
to 2.50
H4-02:
1.00
H4-05:
0.50
5-52
L3-04
Stall
prevention
selection
during
deceleration
If
using the dynamic brake option (Braking
Resistor,
Braking Resistor Units, and Brak-
ing
Units), be sure to set parameter L3-04 to
0
(disabled) or 3 (enabled with Braking
Resistor).
0
to 3
1
5-60
6-25
Table 4.2 Parameters that must be set (Continued)
Parame-
ter Num-
ber
Name
Description
Setting Range
Factory
Setting
Page