Parameter Tables
5-
9
Parameter
Tables
K
K
K
K
A:
Setup
Settings
The
following settings are made with the environment parameters (A parameters): Language displayed on the
Digital
Operator, access level, control method, initialization of parameters.
n
Initialize
Mode:
A1
Parameters
for the environment modes are shown in the following table.
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
A1-00
Language
selection
for
Digital
Operator
display
Used
to select the language
displayed
on the Digital
Operator
(LED).
0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
This
parameter is not initial-
ized
by the initialize opera-
tion.
0
to 6
1
Yes
A
A
A
100H
-
Select
Lan-
guage
A1-01
Parameter
access
level
Used
to set the parameter
access
level (set/read.)
0: Monitoring
only
(Monitoring
drive mode
and
setting A1-01 and
A1-04.)
1: Used
to select parameter
(Only
parameters set in
A2-01
to A2-32 can be
read
and set.)
2: Advanced
(Parameters
can be read
and
set in both quick
programming
mode and
advanced
programming
(A)
mode.)
0
to 2
2
Yes
A
A
A
101H
6-141
6-142
Access
Level
A1-02
Control
method
selection
Used
to select the control
method
for the Inverter
0:
V/f control
1:
V/f with PG feedback
(Pulse
generator as
encoder)
2:
Open loop vector
This
parameter is not initial-
ized
by the initialize opera-
tion.
0
to 2
0
No
Q
Q
Q
102H
4-7
4-9
4-18
Control
Method
Содержание SYSDRIVE 3G3RV
Страница 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Страница 36: ...1 22...
Страница 106: ...3 14...
Страница 126: ...4 20...
Страница 216: ...5 90...
Страница 388: ...7 26...