1
-6
Table
1.4
Differences
in
Software
(Continued)
Name
Parameter
Number
Asia
Europe
suffixed
-E
LCD
brightness
adjustment
o1-05
Cannot
change.
Setting
Range: 0 to 5
Adjusts
the brightness in five steps.
Operation
selection
when
Digital Opera-
tor
is disconnected
o2-06
Factory
setting
0
(Disabled)
Factory
setting
0
(Disabled)
Cumulative
opera-
tion
time selection
o2-08
Factory
setting = 0
(Cumulative
time when the Inverter
power
is ON)
Factory
setting = 1
(Cumulative
Inverter run time)
Fault
trace and fault
history
initialization
o2-12
Cannot
clear
0:
Disabled
(U2, U3 are held.)
1:
Initialize Enabled
(U2,
U3 are cleared and o2-12 returns
to
0.)
Fault
history
U3-01
to U3-20
Four
fault history records are stored.
U3-01
to U3-08 are enabled.
Serial
communications addresses 90H
to
97H are enabled. (800H to 813H are
disabled)
Ten
fault history records are stored.
U3-01
to U3-20 are enabled.
Serial
communications addresses
800H
to 813H and 90H to 97H are
both
enabled.