Parameter Tables
5-
39
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
F1-04
Operation
selection
at
deviation
Sets
the stopping method
when
a speed deviation
(DEV)
fault occurs.
0: Ramp
to stop
(Deceleration
stop using
Deceleration
Time 1, C1-
02.)
1: Coast
to stop
2: Fast
stop (Emergency
stop
using the
deceleration
time in C1-
09.)
3: Continue
operation (DEV
is
displayed and
operation
continued.)
0
to 3
3
No
No
A
No
383H
6-143
PG
Devia-
tion
Sel
F1-05
PG
rotation
0: Phase
A leads with
forward
run command.
(Phase
B leads with
reverse
run command.)
1: Phase
B leads with
forward
run command.
(Phase
A leads with
reverse
run command.)
0
or 1
0
No
No
A
No
384H
6-143
PG
Rota-
tion
Sel
F1-06
PG
division
rate
(PG
pulse
moni-
tor)
Sets
the division ratio for the
PG
Speed Control Card
pulse
output.
Division
ratio = (1+ n) /m
(n=0
or 1 m=1 to 32)
This
parameter is only effec-
tive
when a PG-B2 is used.
The
possible division ratio
settings
are: 1/32
≤
F1-06
≤
1.
1
to
132
1
No
No
A
No
385H
6-144
PG
Output
Ratio
F1-07
Integral
value
during
accel/decel
enable/dis-
able
Sets
integral control during
acceleration/deceleration
to
either
enabled or disabled.
0: Disabled
(The integral
function
isn't used while
accelerating
or
decelerating;
it is used at
constant
speeds.)
1: Enabled
(The integral
function
is used at all
times.)
0
or 1
0
No
No
A
No
386H
6-144
PG
Ramp
PI/I
Sel
F1-06
n
m