Differences
by
Model
1-
5
Table
1.4
Differences
in
Software
(Continued)
Name
Parameter
Number
Asia
Europe
suffixed
-E
Torque
value setting
C4-03
to
C4-05
Disabled
C4-03/C4-04:
Set the rated torque of
the
motor.
C4-05:
Set the time constant (ms) for
the
rising start torque value.
Note:
The filter is disabled if set
between
0 ms and 4 ms.
Motor
constant
E1/E3
Factory
setting
200-V
class = 200 V 60 Hz
400-V
class = 400 V 60 Hz
Factory
setting
200-V
class = 200 V 50 Hz
400-V
class = 400 V 50 Hz
PG
constant
F1-01
Factory
setting
600
pulses/rotation
Factory
setting
1024
pulses/rotation
Display
unit selec-
tion
for current moni-
tor
F6-05
Disabled
Setting
range 0 to 1
0:
Amperage display
1:
100% for 8192
Multi-function
inputs H1-01 to H1-05
Setting
range: 0 to 68
69
and 6A: Disabled
Setting
range: 0 to 6 A
69:
JOG2
6A:
Drive Enable
0
to 68: Same for all models
Multi-function
out-
puts
H2-02
Terminal
P1 function
select
Terminal
M3-M4 function select
(Transistor
output)
H2-03
Terminal
P2 function
select
Terminal
M5-M6 function select
(Transistor
output)
Signal
select termi-
nal
A1 (voltage)
H3-01
Disabled
with 0 setting.
0:
Voltage Limit enabled unchange-
able
Setting
range: 0 or 1
0:
Voltage Limit enabled
1:
Voltage Limit disabled
Gain
(terminal FM)
H4-02
Setting
range
0.0
to 2.5
Factory
setting 1.00
Setting
range
0.0
to 1000.0%
Factory
setting
100.0%
Gain
(terminal AM)
H4-05
Setting
range
0.0
to 2.5
Factory
setting
0.50
Setting
range
0.0
to 1000.0%
Factory
setting
50.0%
Bias
(terminal FM)
H4-03
Setting
range
-10.0%
to +10.0%
Setting
range
-110.0%
to +110.0%
Bias
(terminal AM)
H4-06
Setting
range
-10.0%
to +10.0%
Setting
range
-110.0%
to +110.0%
Analog
output 1
signal
level selection
H4-07
Setting
range: 0 to 1
Setting
range: 0 to 2
Analog
output 2 sig-
nal
level selection
H4-08
0:
0 to +10 V
1:
-10 to +10 V
0:
0 to +10 V
1:
-10 to +10 V
2:
4 to 20 mA
Frequency
reference
for
loss of frequency
reference
L4-06
Uses
the factory setting value (80%)
and
unchangeable.
Set
reference frequency for operation
when
frequency lost.
The
output frequency is (Specified
Frequency)
x L4-06.
Input
open-phase pro-
tection
selection
L8-05
Factory
setting
0
(Disabled)
Factory
setting
1
(Enabled)
Output
open-phase
protection
selection
L8-07
Factory
setting
0
(Disabled)
Factory
setting
1
(Enabled)