10
-10
K
K
K
K
Using an Analog Operator
This
example shows wiring for using an Analog Operator. The Analog Operator model number is 3G3IV-
PJVOP95
o
or 3G3IV-PJVOP96
o
.
This
example shows wiring for the 3G3RV-A2075 (200-V class Inverters of 7.5 kW)
Fig 10.6
MCCB
3-phase power
Inverter
Motor
Ground to 100
max.
Forward run command
(forward run when closed)
Reverse run command
(reverse run when closed)
Multi-function contact inputs
Sequence common (0 V)
Shield terminal
Master speed (0 to 10 V, 20 k
Ω
)
Speed setting power (15 V, 20 mA)
Master speed (4 to 20 mA, 250
Ω
)
Fault contact output
Multi-function contact
output (Default: Running
signal)
3G3IV-PJVOP-95
•
o
,
C-96
•
o
Analog Operator
Frequency meter
Multi-function
analog output
Multi-function
analog output
(Default: Output
frequency)
Open collector 1 (Default:
Zero speed signal)
Open collector 2 (Default:
Speed agreement signal)
Multi-function output
common
Multi-function open-
collector output 48 V,
50 mA max.
Short-circuit bar
(Standard)
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3