Troubleshooting
7-
17
The
operation
method
selection
is
wrong.
If
parameter b1-02 (reference selection) is set to 0 (Digital Operator), the motor will not operate when an
external
operation signal is input. Set b1-02 to 1 (control circuit terminal) and try again.
Similarly,
the motor will also not operate if the LOCAL/REMOTE Key has been pressed to switch to Digital
Operator
operation. In that case press the LOCAL/REMOTE Key* again to return to the original setting.
The
wiring
to
the
Inverter
control
circuit
terminal
is
faulty.
If
the input wiring to the control circuit terminal is faulty, the Inverter input signal cannot be confirmed. Use
the
Digital Operator to check U1-10 (input terminal status).
The
sequence input method can be switched between an NPN (factory setting) and PNP input. For details,
refer
to Chapter 2 Wiring.
A
3-wire
sequence
is
in
effect.
The
input method for a 3-wire sequence is different than when operating by forward/stop and reverse/stop (2-
wire
sequence). When 3-wire sequence is set, the motor will not operate even when an input terminal suitable
for
forward run/stop and reverse run/stop is turned ON.
When
using a 3-wire sequence, refer to the timing chart and input the proper signals.
When
using a 2-wire sequence, set the multi-function input terminal (H1-01 through H1-05, terminals S3 to
S7)
to a value other than 0.
The
frequency
reference
is
too
low.
If
the frequency reference is set below the frequency set in E1-09 (Minimum Output Frequency), the Inverter
will
not operate. Raise the frequency reference to at least the minimum output frequency.
There
is
a
multi-function
analog
input
setting
error.
If
multi-function analog inputs H3-05 and H3-09 are set to 1 (frequency gain), and if no voltage (current) is
input,
then the frequency reference will be zero. Check to be sure that the set value and analog input value are
correct.
n
The
motor
stops
during
acceleration
or
when
a
load
is
connected.
The
load may be too heavy. The Inverter has a stall prevention function and an automatic torque boost func-
tion,
but the motor responsiveness limit may be exceeded if acceleration is too rapid or if the load is too heavy.
Lengthen
the acceleration time or reduce the load. Also consider increasing the motor capacity.
n
The
motor
only
rotates
in
one
direction.
“Reverse
run prohibited” is selected. If b1-04 (Prohibition of Reverse Operation) is set to 1 (reverse run pro-
hibited),
the Inverter will not receive reverse run commands. To use both forward and reverse operation, set
b1-04
to 0.
INFO
The LOCAL/REMOTE Key is enabled by setting o2-01 to 1 and disabled by setting o2-01 to 2. It is enabled
when the drive mode is entered.
Содержание SYSDRIVE 3G3RV
Страница 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Страница 36: ...1 22...
Страница 106: ...3 14...
Страница 126: ...4 20...
Страница 216: ...5 90...
Страница 388: ...7 26...