Options and Peripheral Devices
9-
7
* 1. Recommended
Options can be ordered from OMRON using the above model numbers.
* 2. Not
applicable to (-E) models.
Table 9.1 Options and Peripheral Devices
Type
Name
Model
number
Application
Special
Mounted
Options
Fan
Unit
3G3IV-PFAN
@
Replacement
fan for Inverters equipped with a cooling fan.
Replace
the Cooling Fan when the fan replacement time has come or a cooling fan fault
(FAN)
alarm has been displayed.
Separately
Installed
Options
Scaling
Meter
K3TJ-V11
@
Connects
to a multi-function analog output from the Inverter.
Used
to display rotational speeds of motors, line speeds, etc., in physical units.
Analog
Operator (stan-
dard
with steel panels)
3G3IV-PJVOP96
@
Allows
frequency reference settings and ON/OFF operation control to be performed by
analog
references from a remote location (50 m max.).
Frequency
counter specifications: 75 Hz, 150 Hz, 220 Hz
Analog
Operator (small,
plastic)
3G3IV-PJVOP95
@
Allows
frequency reference settings and ON/OFF operation control to be performed by
analog
references from a remote location (50 m max.).
Frequency
counter specifications: 60/120 Hz, 90/180Hz
Special
Options
Braking
Unit
3G3IV-PCDBR
@
B
Used
with a Braking Resistor Unit to reduce the deceleration time of the motor.
Not
required with Inverters of 7.5 kW or less for 200-V class Inverters or for Inverters of
15
kW or less for 400-V class Inverters.
Braking
Resistor Unit
3G3IV-PLKEB
@
Consumes
the regenerative motor energy with a resistor to reduce deceleration time (use
rate:
10% ED).
Braking
Resistor
3G3IV-PERF150WJ
@
01
Consumes
the regenerative motor energy with a resistor to reduce deceleration time (use
rate:
3% ED).
Not
required with Inverters of 3.7 kW or less for 200-V class Inverters or for Inverters of
2.2
kW or less for 400-V class Inverters.
DC
Reactor
3G3HV-PUZDAB
@
Used
to control harmonics generated by the Inverter and to improve the input power fac-
tor
of the Inverter. All Inverters of 18.5 kW or higher contain built-in DC reactors.
Digital
Operator with
LCD
Display
3G3IV-PJVOP160
Displays
messages on an LCD.
Digital
Operator with
LED
Display
3G3IV-PJVOP161
Display
messages on an LED display. Standard in Asia and Europe.
Digital
Operator Connec-
tion
Cable
3G3IV-PCN126
(1 m)
Extension
cable to use a 3G3RV-series Digital Operator remotely.
Cable
length: 1 m or 3 m
3G3IV-PCN326
(3 m)
Option
Cards
Analog
Monitor Cards*2
3G3IV-PAO08
The
resolution of the analog output from the Inverter is 11 bits. Use this Card if there are
not
enough analog outputs.
The
output resolution of the 3G3IV-PAO08 is (0 to 10 V output for frequency meters or
output
current meters) and the output resolution of the 3G3IV-PAO12 is 1/2048 (0 to
10
V for control applications).
3G3IV-PAO12
PG
Speed Control Cards
3G3FV-PPGA2
Phase-A
(single-phase) pulse input and open collector output for V/f control with a PG.
Maximum
response frequency: 30 kHz, with pulse monitor output.
3G3FV-PPGB2
Phase-A/B
pulse inputs and open collector output for flux vector control.
Maximum
response frequency: 30 kHz, with pulse monitor output.
3G3FV-PPGD2
Phase-A
(single-phase) pulse input and line driver output (RS-422) for V/f control with a PG.
Maximum
response frequency: 300 kHz, with pulse monitor output.
3G3FV-PPGX2
Phase-A/B/Z
pulse inputs and line driver output (RS-422) for flux vector control.
Maximum
response frequency: 300 kHz, with pulse monitor output
DeviceNet
Communica-
tions
Card
3G3FV-PDRT1-SIN
Used
for DeviceNet communications with a Programmable Controller or other
DeviceNet
master device.
Recommended
Separately
Installed
Options
*1
AC
Reactor (Yaskawa)
3G3IV-PUZBAB
@
Used
to control harmonics generated by the Inverter or when the power supply capacity
is
greatly larger than the Inverter’s capacity. Also used to increase the power factor.
Simple
Input Noise Filter
(Yaskawa)
3G3EV-PLNFD
@
Reduces
noise coming into the inverter from the power supply line and to reduce noise
flowing
from the inverter into the power supply line. Connected to the power supply
input
side.
Input
Noise Filter
(Schaffner)
3G3IV-PFN
@
Reduces
noise coming into the inverter from the power supply line and to reduce noise
flowing
from the inverter into the power supply line.Connected to the power supply
input
side.
Input
Noise Filter
(Schaffner)
for EMC
Directive
3G3RV-PFS
o
Required
for the 3GRV Inverter to meet the EMC Directive.
Output
Noise Filter
(Tokin)
3G3IV-PLF
@
Controls
noise generated by the Inverter so it does not enter the power supply. Con-
nected
to the motor output side.