Parameter Tables
5-
33
* 1. These
are values for a 200-V class Inverter. Values for a 400-V class Inverter are double.
* 2. The
factory setting will change when the control method is changed. (V/f control factory settings are given.)
* 3. E1-11
and E1-12 are disregarded when set to 0.0.
* 4. E1-13
is set to the same value as E1-05 by autotuning.
* 5. When
C6-01 is set to 0, the upper limit of the setting range is 150.0 Hz.
* 6. For
(-E) models. Factory setting for base frequency is 50 Hz.
n
Motor
Setup:
E2
Parameters
for motor 1 are shown in the following table.
E1-11
Mid.
output
frequency
2
Set
only to fine-adjust V/f for the
output
range. Normally, this setting
is
not required.
0.0
to
400.0
0.0
Hz
*3
No
A
A
A
30AH
6-129
Mid
Frequency
B
E1-12
Mid.
output
frequency
voltage
2
0.0
to
255.0
*1
0.0
V
*3
No
A
A
A
30BH
6-129
Mid
Voltage
B
E1-13
Base
voltage
0.0
to
255.0
*1
0.0
V
*4
No
A
A
Q
30CH
6-129
Base
Voltage
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
E2-01
Motor
rated
current
Sets
the motor rated current
in
1 A units.
These
set values will become
the
reference values for
motor
protection and torque
limits.
This
parameter is automati-
cally
set during autotuning.
0.32
to
6.40
*2
1.90
A
*1
No
Q
Q
Q
30EH
6-47
6-127
Motor
Rated
FLA
E2-02
Motor
rated
slip
Sets
the motor rated slip in
Hz
units.
These
set values will become
the
reference values for slip
compensation.
This
parameter is automati-
cally
set during autotuning.
0.00
to
20.00
2.90
Hz
*1
No
A
A
A
30FH
6-127
Motor
Rated
Slip
E2-03
Motor
no-
load
current
Sets
the motor no-load cur-
rent
in 1 A units.
This
parameter is automati-
cally
set during autotuning.
0.00
to
1.89
*3
1.20
A
*1
No
A
A
A
310H
6-127
No-Load
Current
E2-04
Number
of
motor
poles
Sets
the number of motor
poles.
This
parameter is automati-
cally
set during autotuning.
2
to 48 4 poles
No
No
Q
No
311H
6-127
Number
of
Poles
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register
Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
Содержание SYSDRIVE 3G3RV
Страница 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Страница 36: ...1 22...
Страница 106: ...3 14...
Страница 126: ...4 20...
Страница 216: ...5 90...
Страница 388: ...7 26...