Installing and Wiring Option Cards
2-
55
K
K
K
K
Selecting
the
Number
of
PG
(Encoder)
Pulses
The
setting for the number of PG pulses depends on the model of PG Speed Control Card being used. Set the
correct
number for your model.
n
3G3FV-PPGA2/3G3FV-PPGB2
The
maximum response frequency is 32,767 Hz.
Use
a PG that outputs a maximum frequency of approximately 20 kHz for the rotational speed of the motor.
Some
examples of PG output frequency (number of pulses) for the maximum frequency output are shown in
Table
2.31.
Note 1. The
motor speed at maximum frequency output is expressed as the sync rotation speed.
2. The
PG power supply is 12 V.
3. A
separate power supply is required if the PG power supply capacity is greater than 200 mA. (If momentary power loss must be handled, use a
backup
capacitor or other method.)
Fig 2.42 3G3FV-PPGB2 Connection Example
Table 2.31 PG Pulse Selection Examples
Motor's
Maximum
Speed
(r/min)
PG
Rating
(p/rev)
PG
Output
Frequency
for
Maximum
Fre-
quency
Output
(Hz)
1800
600
18,000
1500
800
20,000
1200
1000
20,000
900
1200
18,000
Motor
speed at maximum frequency output (r/min)
60
--------------------------------------------------------------------------------------------------------------------------
PG
rating (p/rev)
×
20,000
Hz
=
PG power supply
Capacitor for momentary
power loss
Signals