Individual Functions
6-
127
K
K
K
K
Setting
Motor
Constant
Parameters
In
vector control method, the motor constant parameter are set automatically using autotuning. If autotuning
does
not complete normally, set them manually.
n
Related
Parameters
Note All
factory-set parameters are for a standard 4-pole motor.
* 1. The
factory settings depend on Inverter capacity (the values shown are for a 200 V Class Inverter for 0.4 kW).
* 2. The
setting range is 10% to 200% of the Inverter rated output current (the values shown are for a 200 V Class Inverter for 0.4 kW).
* 3. The
setting range depends on Inverter capacity (the values shown are for a 200 V Class Inverter for 0.4 kW).
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
E2-01
Motor
rated current
Sets
the motor rated current in 1 A units.
These
set values will become the reference values
for
motor protection and torque limits.
This
parameter is automatically set during auto-
tuning.
0.32
to
6.40
*2
1.90
A
*1
No
Q
Q
Q
Motor
Rated FLA
E2-02
Motor
rated slip
Sets
the motor rated slip in Hz units.
These
set values will become the reference values
for
slip compensation.
This
parameter is automatically set during auto-
tuning.
0.00
to
20.00
2.90
Hz
*1
No
A
A
A
Motor
Rated Slip
E2-03
Motor
no-load current
Sets
the motor no-load current in 1 A units.
This
parameter is automatically set during auto-
tuning.
0.00
to
1.89
*3
1.20
A
*1
No
A
A
A
No-Load
Current
E2-04
Number
of motor poles
Sets
the number of motor poles.
This
parameter is automatically set during auto-
tuning.
2
to 48
4
poles
No
No
Q
No
Number
of Poles
E2-05
Motor
line-to-line resis-
tance
Sets
the motor phase-to-phase resistance in
Ω
units.
This
parameter is automatically set during auto-
tuning.
0.000
to
65.000
9.842
Ω
*1
No
A
A
A
Term
Resistance
E2-06
Motor
leak inductance
Sets
the voltage drop due to motor leakage induc-
tance
as a percentage of the motor rated voltage.
This
parameter is automatically set during auto-
tuning.
0.0
to
40.0
18.2%
No
No
No
A
Leak
Inductance
E2-07
Motor
iron saturation coef-
ficient
1
Sets
the motor iron saturation coefficient at 50%
of
magnetic flux.
This
parameter is automatically set during auto-
tuning.
0.00
to
0.50
0.50
No
No
No
A
Saturation
Comp1
E2-08
Motor
iron saturation coef-
ficient
2
Sets
the motor iron saturation coefficient at 75%
of
magnetic flux.
This
parameter is automatically set during auto-
tuning.
0.00
to
0.75
0.75
No
No
No
A
Saturation
Comp2
E2-10
Motor
iron loss for torque
compensation
Sets
motor iron loss in W units.
0
to
65535
14
W
*1
No
A
A
No
Tcomp
Iron Loss
Содержание SYSDRIVE 3G3RV
Страница 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Страница 36: ...1 22...
Страница 106: ...3 14...
Страница 126: ...4 20...
Страница 216: ...5 90...
Страница 388: ...7 26...