5
-80
Note The
following errors are not included in the error trace: CPF00, 01, 02, 03, UV1, and UV2.
n
Fault
History:
U3
Parameters
for the error log are shown in the following table.
U2-10
Torque
ref-
erence
at
fault
The
reference torque when the
previous
fault occurred. The
motor
rated torque corresponds
to
100%.
(Cannot
be output.)
0.1%
No
No
A
89H
Torque
Ref-
erence
U2-11
Input
termi-
nal
status at
fault
The
input terminal status when
the
previous fault occurred.
The
format is the same as for
U1-10.
-
A
A
A
8AH
Input
Term
Sts
U2-12
Output
ter-
minal
status
at
fault
The
output terminal status when
the
previous fault occurred. The
format
is the same as for U1-11.
-
A
A
A
8BH
Output
Term
Sts
U2-13
Operation
status
at
fault
The
operating status when the
previous
fault occurred. The
format
is the same as for U1-12.
-
A
A
A
8CH
Inverter
Sta-
tus
U2-14
Cumulative
operation
time
at fault The operating time when the
previous
fault occurred.
1
hr
A
A
A
8DH
Elapsed
time
Param-
eter
Number
Name
Description
Output Signal Level Dur-
ing Multi-Function Analog
Output
Min.
Unit
Control Methods
Register
LCD
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
U3-01
Most
recent
fault
The
error contents of 1st
previous
fault.
(Cannot
be output.)
-
A
A
A
90H
(800H)
Last
Fault
U3-02
Second
most
recent
fault
The
error contents of 2nd
previous
fault.
-
A
A
A
91H
(801H)
Fault
Mes-
sage
2
U3-03
Third
most
recent
fault The error contents of 3rd
previous
fault.
-
A
A
A
92H
(802H)
Fault
Mes-
sage
3
Param-
eter
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
Register
LCD
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Содержание SYSDRIVE 3G3RV
Страница 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Страница 36: ...1 22...
Страница 106: ...3 14...
Страница 126: ...4 20...
Страница 216: ...5 90...
Страница 388: ...7 26...