Digital Operator Functions
6-
135
Digital
Operator
Functions
This
section explains the Digital Operator functions.
K
K
K
K
Setting
Digital
Operator
Functions
You
can set Digital Operator-related parameters such as selecting the Digital Operator display, multi-function
selections,
and copy functions.
n
Related
Parameters
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
o1-02
Monitor
selection after
power
up
Set
the monitor item to be displayed when the
power
supply is turned ON.
1:
Frequency reference
2:
Output frequency
3:
Output current
4:
The monitor item set for o1-01
1
to 4
1
Yes
A
A
A
Power-On
Monitor
o1-03
Frequency
units of refer-
ence
setting and monitor
Sets
the units that will be set and displayed for the
frequency
reference and frequency monitor.
0:
0.01
Hz units
1:
0.01%
(Maximum output fre-
quency
is 100%)
2
to 39:
r/min
units (Sets the motor poles)
40
to 39999: User desired display
Set
the desired values for setting
and
display for the max. output
frequency.
Example:
When the max. output frequency value
is
200.0, set 12000.
0
to
39999
0
No
A
A
A
Display
Scaling
o2-01
LOCAL/REMOTE
key
enable/disable
Set
the run method selection key (LOCAL/
REMOTE
Key) function.
0:
Disabled
1:
Enabled (Switches between the Digital Opera-
tor
and the parameter settings.)
0
or 1
1
No
A
A
A
Local/Remote
Key
o2-02
STOP
Key during control
circuit
terminal operation
Set
the STOP Key in the run mode.
0:
Disabled (When the run command is issued
from
an external terminal, the Stop Key is dis-
abled.)
1:
Enabled (Effective even during run.)
0
or 1
1
No
A
A
A
Oper
STOP Key
o2-03
Parameter
initial value
When
the frequency reference is set on the Digital
Operator
frequency reference monitor, sets
whether
the Enter key is necessary.
0:
Enter Key needed
1:
Enter Key not needed
2:
All clear (clears all recorded user initial val-
ues)
When
set to 1, the Inverter accepts the frequency
reference
without Enter Key operation.
0
to 2
0
No
A
A
A
User
Defaults
Set 4-digit number
excluding the decimal
point.
Set the number of digits
below the decimal point
to display.