6
-60
Inverter
Protection
This
section explains the functions for protecting the Inverter and the braking resistor.
K
K
K
K
Performing
Overheating
Protection
on
Mounted
Braking
Resistors
Perform
overheating protection on Inverter-mounted braking resistors (3G3IV-PERF
o
).
When
overheating in a mounted braking resistor is detected, an alarm RH (Mounted braking resistor overheat-
ing)
is displayed on the Digital Operator, and the motor coasts to a stop.
n
Related
Parameters
Multi-function
Digital
Outputs
(H2-01
to
H2-03)
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
L8-01
Protect
selection for inter-
nal
DB resistor
0:
Disabled (no overheating protection)
1:
Enabled (overheating protection)
0
or 1
0
No
A
A
A
DB
Resistor Prot
Set
Value
Details
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
D
Braking
resistor fault (ON: Resistor overheats or brake transistor fault)
Yes
Yes
Yes
INFO
The most likely causes of RH (Mounted braking resistor overheating) being detected are that the deceleration
time is too short or that the motor regeneration energy is too large. In these cases, lengthen the deceleration
time or replace the Braking Resistor Unit with one with a higher breaking capacity.