Communications Functions
6-
85
Note Write
0 to all unused bits. Also, do not write data to reserved registers.
Monitor
Data
The
following table shows the monitor data. Monitor data can only be read.
000FH
Reference
selection settings
Bit
0
Not
used
Bit
1
PID
target value (register 0006H) 1: Enabled 0: Disabled
Bits
3 to B
Not
used
C
Broadcast
data S5 1: Enabled 0: Disabled
D
Broadcast
data S6 1: Enabled 0: Disabled
E
Broadcast
data S7 1: Enabled 0: Disabled
F
Not
used
Register
No.
Contents
0020H
Inverter
status
Bit
0
Operation
1: Operating 0: Stopped
Bit
1
Reverse
operation 1: Reverse operation 0: Forward operation
Bit
2
Inverter
startup complete 1: Completed 2: Not completed
Bit
3
Error
1: Error
Bit
4
Data
setting error 1: Error
Bit
5
Multi-function
contact output (terminal M1 - M2) 1: ON 0: OFF
Bit
6
Multi-function
output 1 (terminal P1 - PC) (M3-M4)1: ON 0: OFF
Bit
7
Multi-function
output 2 (terminal P2 - PC) (M5-M6) 1: ON 0: OFF
Bits
8 to F
Not
used
0021H
Error
details
Bit
0
Overcurrent
(OC) Ground fault (GF)
Bit
1
Main
circuit overvoltage (OV)
Bit
2
Inverter
overload (OL2)
Bit
3
Inverter
overheat (OH1, OH2)
Bit
4
Injection
brake transistor resistance overheat (rr, rH)
Bit
5
Fuse
blown (PUF)
Bit
6
PID
feedback reference lost (FbL)
Bit
7
External
error (EF, EFO)
Bit
8
Hardware
error (CPF)
Bit
9
Motor
overload (OL1) or overtorque 1 (OL3) detected
Bit
A
PG
broken wire detected (PGO), Overspeed (OS), Speed deviation (DEV)
Bit
B
Main
circuit undervoltage (UV) detected
Bit
C
Main
circuit undervoltage (UV1), control power supply error (UV2), inrush preven-
tion
circuit error (UV3), power loss
Bit
D
Missing
output phase (LF)
Bit
E
RS-422A/485
communications error (CE)
Bit
F
Operator
disconnected (OPR)
Register
No.
Contents