7 Before Starting Positioning Operation
52
FX
3U
-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
6) Set to ON from OFF the positioning parameter save command and servo parameter save command.
When saving of parameters is completed, the saving to flash memory flag turns OFF from ON.
→
For control commands, refer to Subsection 11.4.15
7) Perform either of the following operations:
Transfer positioning parameters and servo parameters stored in the flash memory to the buffer memory.
After that, transfer servo parameters to the servo amplifier.
- Performing system reset for the 20SSC-H
a) Write the model code (K5220) to the control command enable/disable.
b) Set the system reset command to ON (and keep it ON for 100 ms or more), and then reset it to OFF.
→
For the operation command 2, refer to the Subsection 11.4.11
- Turning OFF the power of the servo amplifier and PLC (including the 20SSC-H), and then turning it ON
again
a) Turn OFF the power of the servo amplifier and PLC (including the 20SSC-H).
b) Turn ON the power of the servo amplifier.
c) Turn ON the power of the PLC (including the 20SSC-H).
BFM Number
Description
X-axis
Y-axis
Control
command
Positioning parameters
save command
BFM #523
b0
BFM #523
b1
Set this bit to ON from OFF using a sequence program.
Servo parameters save
command
BFM #523
b5
BFM #523
b6
Set this bit to ON from OFF using a sequence program.
Status
information
Saving to flash memory
BFM #28 b11
•
This bit is ON while saving buffer memory data into
the flash memory.
•
When finished storing the data, the bit is cleared.
BFM Number
Description
X-axis
Y-axis
Control command enable/disable
BFM #522
Write K5220 using a sequence program.
BFM Number
Description
X-axis
Y-axis
Operation
command 2
System reset
command
BFM #519 b1
Set this bit to ON (and keep it ON for 100 ms or more), and then
reset it to OFF using a sequence program.