9 Positioning Control
9.9 Linear Interpolation Operation
176
FX
3U
-20SSC-H Positioning Block User's Manual
2. Operation speed
The actual operation speed (vector speed) is "X-axis operation speed 1 x X-axis override setting."
Operation speed 1 for the X-axis can be changed using the operation speed change function except under
the following conditions.
→
For change of the operation speed, refer to Section 7.6
• During deceleration operation
• When the speed change disable during operation signal is ON.
3. Address specification
The absolute/relative address can be specified.
With the specified absolute address: Specifies a target address (position) using address 0 as the base.
With the specified relative address: Specifies a travel amount from the current address.
4. Rotation Direction
With the specified absolute address: The rotation direction depends on whether the target address 1 is
larger or smaller than the current address.
With the specified relative address: The rotation direction is decided by the sign (positive/negative) of target
address 1.