7 Before Starting Positioning Operation
98
FX
3U
-20SSC-H Positioning Block User's Manual
7.6 Changing During Operation (Operation Speed, Target Address)
7.6.3
Changing target address during operation using target address change function
This function is used to change the target address in positioning control to a new specified address.
→
For the parameters, control data and monitor data, refer to Chapter 11
1. Set the following when changing the target address and operation speed during operation
using the target address change function.
*1.
Refer to the section shown below for details on the user units.
→
Refer to Section 7.10
Note
To leave the operation speed unchanged, set the target position change value (speed) to the same speed as
the current operation speed.
2. Applicable positioning operations
3. Operation
]
BFM Number
Description
X-axis
Y-axis
Operation
command 1
Change command
in operation
disabled
BFM #518
b12
BFM #618
b12
Set these bits to OFF.
While these bits are ON, the speed change command in positioning
operation and target position change command is disabled.
Target position
change command
in positioning
operation
BFM #518
b14
BFM #618
b14
Set these bits to ON from OFF.
When these bits are set to ON from OFF, the target address during
operation is changed to the address and speed set in the target
position change value (address) and target position change value
(speed).
Target position change value
(address)
BFM #515,
#514
BFM #615,
#614
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
*1
Set the value within -2,147,483,648 to 2,147,483,647 PLS in converted
pulse data.
Target position change value
(speed)
BFM #517,
#516
BFM #617,
#616
Setting range: 1 to 2,147,483,647 [User unit]
*1
Set the value within 1 to 50,000,000 Hz in converted pulse data.
• Operations applicable to the target address
change function
• Operations inapplicable to the target address
change function
- 1-speed positioning operation
- Interrupt 1-speed constant quantity feed
- 2-speed positioning operation
- Interrupt 2-speed constant quantity feed
- Interrupt stop
- Reciprocal movement instruction
(Ver.1.10 or later)
- Mechanical zero return
- Manual pulse generator operation
- JOG operation
- Variable speed operation
- Multi-speed operation
- Linear interpolation
- Linear interpolation (interrupt stop)
- Circular interpolation
BFM Number
Data type
X-axis
Y-axis
Operation speed setting
Operation speed 1
BFM #503,#502
BFM #603,#602
Control data
Operation speed 2
BFM #507,#506
BFM #607,#606
Control data
ON
ON
OFF
OFF
Speed
New operation speed
Operation speed
New target address
Target position change command
(speed) in positioning operation
Target address
Time
Changing target address