Note
• When the 20SSC-H completes positioning in the open or close position, the positioning completion signal
turns ON.
• The READY status remains OFF while the 20SSC-H is operating, and turns ON when the 20SSC-H
finishes operation.
• The motor decelerates and stops when the operation pattern selection (reciprocal movement instruction) is
set to OFF.
• When changing the address to a newly specified one during control using the target address change
function, the target address after change becomes valid when the target address 1 or target address 2 is
changed at the same time.
- When changing the target address (open position) during the opening operation, change the target
address 1 at the same time.
- When changing the target address (close position) during the closing operation, change the target
address 2 at the same time.
• When using the reciprocal movement instruction in ring operation, set the ring operation direction for
absolute address to "0: Direction for shorter rotation."
BFM Number
Data type
X-axis
Y-axis
Standby for remaining travel
distance at stop
Status information
BFM #28 b7
BFM #128 b7
Monitor data
Received target address (Ver.1.20 or later)
BFM #25,#24
BFM #125,#124
Monitor data
Received target speed (Ver.1.20 or later)
BFM #27,#26
BFM #127,#126
Monitor data
Current address (user)
BFM #1,#0
BFM #101,#100
Monitor data
Current address (pulse)
BFM #3,#2
BFM #103,#102
Monitor data
Real current address (user) (Ver.1.20 or later)
BFM #21,#20
BFM #121,#120
Monitor data
Real current address (pulse) (Ver.1.20 or later)
BFM #23,#22
BFM #123,#122
Monitor data
Operation speed present value
BFM #11,#10
BFM #111,#110
Monitor data
System of units (user unit)
Operation parameter 1
BFM #14000 b1,b0
BFM #14200 b1,b0
Positioning parameters
Unit of measurement for the user
units
Operation parameter 1
BFM #14000 b3,b2
BFM #14200 b3,b2
Positioning parameters
Position data magnification
Operation parameter 1
BFM #14000 b5,b4
BFM #14200 b5,b4
Positioning parameters
Acceleration/deceleration mode
Operation parameter 1
BFM #14000 b11
BFM #14200 b11
Positioning parameters
STOP mode
Operation parameter 1
BFM #14000 b15
BFM #14200 b15
Positioning parameters
Servo end check enabled/disabled
Operation parameter 2
BFM #14002 b0
BFM #14202 b0
Positioning parameters
Servo ready check enabled/
disabled
Operation parameter 2
BFM #14002 b1
BFM #14202 b1
Positioning parameters
Ring counter setting (Ver.1.10 or
later)
Operation parameter 2
BFM #14002 b3
BFM #14202 b3
Positioning parameters
Pulse rate
BFM #14005,#14004 BFM #14205,#14204 Positioning parameters
Feed rate
BFM #14007,#14006 BFM #14207,#14206 Positioning parameters
Maximum speed
BFM #14009,#14008 BFM #14209,#14208 Positioning parameters
Acceleration time
BFM #14018
BFM #14218
Positioning parameters
Deceleration time
BFM #14020
BFM #14220
Positioning parameters
Servo end evaluation time
BFM #14032
BFM #14232
Positioning parameters
Ring counter upper limit value (Ver. 1.10 or later)
BFM #14101,#14100 BFM #14301,#14300 Positioning parameters
Positioning completion signal output waiting time
(Ver.1.20 or later)
BFM #14106
BFM #14306
Positioning parameters
Acceleration time 2 (Ver.1.30 or later)
BFM #14108
BFM #14308
Positioning parameters
Deceleration time 2 (Ver.1.30 or later)
BFM #14110
BFM #14310