Appendix A: LIST OF PARAMETERS AND DATA
Appendix A-2 Control Data Table
282
FX
3U
-20SSC-H Positioning Block User's Manual
Appendix A-2 Control Data Table
BFM number
Item
Description/Setting range
Default
value
Reference
X axis
Y axis
BFM
#501,#500
BFM
#601,#600
Target address1
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0
Subsection 11.4.1
BFM
#503,#502
BFM
#603,#602
Operation speed1
1 to 2,147,483,647 (user unit)
*1
*2
K1
Subsection 11.4.2
BFM
#505,504
BFM
#605,#604
Target address2
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0
Subsection 11.4.3
BFM
#507,#506
BFM
#607,#606
Operation speed2
1 to 2,147,483,647 (user unit)
*1
*2
K1
Subsection 11.4.4
BFM #508
BFM #608
Override setting
1 to 30000 (
×
0.1%)
K1000
Subsection 11.4.5
BFM #510
BFM #610
Torque output setting
value
0 to 10000 (
×
0.1%)
K0
Subsection 11.4.6
BFM
#513,#512
BFM
#613,#612
Speed change value
1 to 2,147,483,647 (user unit)
*1
*2
K1
Subsection 11.4.7
BFM
#515,#514
BFM
#615,#614
Target position
change value
(address)
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0
Subsection 11.4.8
BFM
#517,#516
BFM
#617,#616
Target position
change value
(speed)
1 to 2,147,483,647 (user unit)
*1
K0
Subsection 11.4.9
BFM #518
BFM #618
Operation command 1
b0
Error reset
b1
STOP (Deceleration stop)
b2
Forward rotation limit (LSF)
b3
Reverse rotation limit (LSR)
b4
Forward rotation JOG
b5
Reverse rotation JOG
b6
Mechanical zero return command
b7
Not available
b8
Relative/absolute address specification
b9
START command
b10 Simultaneous START flag
*3
b11 m code OFF
b12 Change command in operation disabled
b13 Speed change command in positioning operation
b14 Target position change command in positioning operation
b15 Not available
H0000
Subsection 11.4.10
BFM #519
BFM #619
Operation command 2
b0
Remaining distance operation cancel command
b1
System reset command (Ver.1.10 or later)
*4
b3, b2
Not available
b4
Positioning parameter enable command
b5
Acceleration/deceleration time change command
(Ver.1.30 or later)
b6
Mode selection for the Interrupt 1-speed constant
quantity feed (Ver.1.10 or later)
b7
Interrupt 1-speed Constant Quantity Feed (Constant
position stop mode) shortest allowable stop
(Ver.1.30 or later)
b8
Servo OFF command
b9
Servo parameter transfer command
b10
Gain change command
b11
Servo parameter update stop (Ver.1.10 or later)
b15 to b12 Not available
H0000
Subsection 11.4.11
BFM #520
BFM #620
Operation pattern
selection
b0
1-speed positioning
b1
Interrupt 1-speed constant quantity feed
b2
2-speed positioning
b3
Interrupt 2-speed constant quantity feed
b4
Interrupt stop
b5
Variable speed operation
b6
Manual pulse generator operation
b7
Linear interpolation
b8
Linear interpolation (interrupt stop)
b9
Table operation (individual)
b10
Table operation (simultaneous)
b11
Reciprocal movement instruction (Ver.1.10 or later)
b15 to b12 Not available
H0000
Subsection 11.4.12