13.1
Check LEDs
13.1.1
Check LEDs
13.1.2
Input LED state indications
LED
Indication
Color
Indication
State
Content of Error
Action
POWER
Green
Off
No power supply from the external
power supply
and PLC main unit.
•
Correctly connect the extension cable and power cable.
•
Correctly connect the wiring to the external power supply.
•
When the service power supply of the PLC main unit is in
use,
make sure that the supply capacity is not being
exceeded.
On
Power is supplied from the external
power supply
and PLC main unit.
The power supply is normal.
X-READY
Y-READY
Green
Off
An error has occurred on the X-axis/
Y-axis, or positioning control is being
executed.
When the stop command is input, the positioning operation
stops, and the LED lights.
If the LED does not light even after a stop, an error has
occuerd. Check the error and remove the cause.
On
The X-axis/Y-axis
cannot accept
operation commands.
-
X-ERROR
Y-ERROR
Red
Off
No error
-
Flashing An error has occurred.
An error has occurred on the 20SSC-H. Check the error code,
and perform the action according to the content of the error.
For details on error codes, refer to the following:
→
Refer to Subsection 13.2.3
On
CPU error
If the 20SSC-H does not restore the problem at power ON
again, consult your local Mitsubishi Electric representative.
LED
Indication
Color
Indication
State
Content of Error
Action
X-START
Y-START
Red
Off
START input OFF
If the LED does not light even if input is ON, check the input
wiring.
The 20SSC-H inputs START, DOG, INT0, and INT1 require
an external power supply (24VDC).
X-DOG
Y-DOG
Red
Off
DOG input OFF
X-INT0
Y-INT0
X-INT1
Y-INT1
Red
Off
INT0, INT1 input OFF
X-
φ
A
Y-
φ
A
Red
Off
Manual pulse generator A-phase
input OFF
If the LED does not flash even at pulse input from the
manual pulse generator, check the input wiring.
X-
φ
B
Y-
φ
B
Red
Off
Manual pulse generator B-phase
input OFF