7 Before Starting Positioning Operation
61
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
7.1 Note on Setting Parameters
To the next page
To the next page
From the previous page
From the previous page
Setting the positioning parameters and servo parameters (X-axis and Y-axis).
T10
M390
Parameter
initialization
program
execution
flag
M380
RST
M510
Resets parameter setting
program completion flag.
SET
M390
Sets parameter setting
program execution flag.
M510
Parameter
setting program
completion flag
Parameter
setting
program
execution flag
FNC 01
CALL
P0
Starts parameter setting
program.
M510
parameter
setting
program
completion
flag
M390
Parameter
setting
program
execution flag
FNC 00
CJ
P63
Create the positioning operation program.
A positioning operation program and a parameter setting program should provide an interlock
in the program not to execute simultaneously.
In this program example, while the parameter setting program is executing, M380, M385 or M390 is ON.
D280.0
D281.0
D283.0
READY/
BUSY
(X-axis)
SET
M391
Ready ON
(X-axis)
M390
READY/
BUSY
(Y-axis)
D285.0
Ready ON
(Y-axis)
FNC 06
FEND
Setting program of positioning parameters and servo parameters (X-axis and Y-axis).
P0
Parameter
setting
program
execution
flag
M391
Initializing the positioning parameters and servo parameters in the buffer memory (X-axis and
Y-axis).
Initialization is not required in the following case.
In this case, this circuit block is unnecessary. And change the contact of T12 to M391.
Enables control commands
in unit No. 1.
Turns ON the initialization
command for each
parameter in unit No. 1.
M392
K5220
U1\G522
FNC 12
MOV
H6300
U1\G523
FNC 12
MOV
SET
M392
When T12 turns ON,
initialization of each
parameter stored in the
buffer memory in unit No. 1
is completed.
It takes 20 ms or more for
initialization of parameters.
T12
K1
When all positioning parameters and servo parameters will be set. (X-axis and Y-axis)