7 Before Starting Positioning Operation
97
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
7.6 Changing During Operation (Operation Speed, Target Address)
From the previous page
From the previous page
M363
Setting the speed command in positioning operation (Y-axis) to ON
SET
D263.D
D263
U1\G618
FNC 12
MOV
SET
M365
Reads the operation
command 1 (Y-axis) in
unit No. 1.
Sets the speed change
command in positioning
(Y-axis) in unit No. 1.
Sets (writes) the operation
command 1 (Y-axis) in
unit No. 1.
U1\G618
D263
FNC 12
MOV
Disabling the change command in operation (X-axis)
M364
D260.D
SET
D262.C
U1\G518
D262
FNC 12
MOV
RST
D262.D
D262
U1\G518
FNC 12
MOV
Reads the operation
command 1 (X-axis) in
unit No. 1.
Sets the change command
in operation disabled
(X-axis) in unit No. 1.
Sets the speed change
command in positioning
(X-axis) in unit No. 1.
Sets (writes) the operation
command 1 (X-axis) in
unit No. 1.
Disabling the change command in operation (Y-axis)
M365
D261.D
SET
D263.C
U1\G618
D263
FNC 12
MOV
RST
D263.D
D263
U1\G618
FNC 12
MOV
Reads the operation
command 1 (Y-axis) in
unit No. 1.
Sets the change command
in operation disabled
(Y-axis) in unit No. 1.
Resets the speed change
command in positioning
(Y-axis) in unit No. 1.
Sets (writes) the operation
command 1 (Y-axis) in
unit No. 1.
SET
M366
SET
M367
M366
M367
M360
M367
FNC 40
ZRST
END
D260
D263
FNC 40
ZRST
M362
Setting the speed command in positioning operation (X-axis) to ON
SET
D262.D
D262
U1\G518
FNC 12
MOV
SET
M364
Reads the operation
command 1 (X-axis) in
unit No. 1.
Sets the speed change
command in positioning
(X-axis) in unit No. 1.
Sets (writes) the operation
command 1 (X-axis) in
unit No. 1.
U1\G518
D262
FNC 12
MOV