12 Program Example
12.3 Explanation of Operation
260
FX
3U
-20SSC-H Positioning Block User's Manual
X-axis
• When turning X007 "X-axis START command" to ON with X022 "X-axis selection of table operation
(individual)" turned ON, multi-speed operation starts with the preset X-axis table information.
After 10,000,000 pulses of travel in the current value incrementing direction, operation decelerates to stop.
• When turning X007 "X-axis START command" to ON after the table operation ends, the positioning
operates by the same travel distance again.
• When turning X001 "X-axis stop" to ON during positioning, the positioning decelerates to stop.
• m codes are output in the with mode. At the start of each operation, the m code ON flag becomes "1" and
the m code number is stored.
When the m code number of 10003, the m code OFF command turns ON, and the m code turns OFF.
Y-axis
• When turning X017 "Y-axis START command" to ON with X023 "Y-axis selection of table operation
(individual)" turned ON, multi-speed operation starts with the preset Y-axis table information.
After 10,000,000 pulses of travel in the current value incrementing direction, operation decelerates to stop.
• When turning X017 "Y-axis START command" to ON after the table operation ends, the positioning
operates by the same travel distance again.
• When turning X011 "Y-axis stop" to ON during positioning, the positioning decelerates to stop.
• m codes are output in the with mode. At the start of each operation, the m code ON flag becomes "1" and
the m code number is stored.
When the m code number of 11003, the m code OFF command turns ON, and the m code turns OFF.
2. Setting table information
Set the X-axis/Y-axis table information as follows in FX Configurator-FP.
1) X-axis table information
2) Y-axis table information