11 Buffer Memory (Parameters & Monitored Data)
11.4 Control Data
242
FX
3U
-20SSC-H Positioning Block User's Manual
POINT
1) When executing the system reset command
Write the model code (K5220) to the "control command enable/disable (BFM #522)" before executing the
system reset command.
→
For system reset, refer to Subsection 7.9.12
→
For the control command enable/disable, refer to Subsection 11.4.14
2) Changing positioning parameters
When the 20SSC-H is powered ON, operation starts with the positioning parameters in the flash memory.
When the buffer memory positioning parameters are changed via FX Configurator-FP or a sequence
program, it is necessary to activate the positioning parameters enable command. Without activating the
command, changes will not be reflected in actual operation. Changing the positioning parameters enable
command must be done when both the Positioning Operation STOP and STOP command state is OFF in
order for the changes to become valid.
3) Transferring servo parameters
a) The following servo parameters are transferred to the servo amplifier when activating the servo
parameter transfer command.
The table below shows transferrable servo parameters depending on the setting of the auto tuning
mode.
*1.
These parameters are automatically adjusted in the interpolation mode.
*2.
These parameters are automatically adjusted in auto tuning mode 1.
*3.
These parameters are automatically adjusted in auto tuning mode 2.
b) During positioning operations or when the STOP command state is ON, the servo parameter transfer
command is ignored.
c) "Transferring servo parameters" in the status information is ON during the transfer.
→
For details on the status information, refer to Subsection 11.3.17
11.4.12 Operation pattern selection [BFM #520, BFM #620]
Auto tuning mode setting status
Interpolation
mode
Auto tuning
mode 1
Auto tuning
mode 2
Manual mode
Auto tuning mode
Auto tuning response
Feed forward gain
Ratio of load inertia moment to servo motor inertia moment
*1
*2
Model loop gain
*2
*3
Position loop gain
*1
*2
*3
Speed loop gain
*1
*2
*3
Speed integral compensation
*1
*2
*3
Speed differential compensation
BFM Number
Bit
Number
Setting Item
Description
Detection
*1
Default
X-axis
Y-axis
BFM
#520
BFM
#620
b0
1-speed
positioning
operation
Set this to perform 1-speed positioning operation.
→
For details on the 1-speed positioning operation,
refer to Section 9.2
Level
H0000
b1
Interrupt 1-speed
constant quantity
feed
Set this to perform an interrupt 1-speed constant quantity
feed.
→
For details on the interrupt 1-speed constant
quantity feed, refer to Section 9.3
b2
2-speed
positioning
operation
Set this to perform 2-speed positioning operation.
→
For details on the 2-speed positioning operation,
refer to Section 9.4
b3
Interrupt 2-speed
constant quantity
feed
Set this to perform an interrupt 2-speed constant quantity
feed.
→
For details on the interrupt 2-speed constant
quantity feed, refer to Section 9.5
b4
Interrupt stop
Set this to perform an interrupt stop.
→