11 Buffer Memory (Parameters & Monitored Data)
11.2 Servo Parameters
223
FX
3U
-20SSC-H Positioning Block User's Manual
11
Buffer
M
e
m
o
ry
12
Pr
ogr
am
Exam
ple
13
D
iagnostics
A
List
of
Par
a
m
e
ter
s and
Da
ta
B
V
e
rs
ion
Infor
m
at
ion
BFM
#15073
BFM
#15273
PC10
Analog monitor 2
output
Select a signal to be output to the analog monitor 2.
0: Servo motor speed (
±
8V at the maximum)
1: Torque (
±
8 V at the maximum)
*B
2: Servo motor speed (+8V at the maximum)
3: Torque (+8 V at the maximum)
*B
4: Current command (
±
8 V at the maximum)
5: Speed command (
±
8V at the maximum)
6: Droop pulses (
±
10 V/1
×
10
2
PLS)
*A
7: Droop pulses (
±
10 V/1
×
10
3
PLS)
*A
8: Droop pulses (
±
10 V/1
×
10
4
PLS)
*A
9: Droop pulses (
±
10 V/1
×
10
5
PLS)
*A
A: Feedback position (
±
10 V/1
×
10
6
PLS)
*A*C
B: Feedback position (
±
10 V/1
×
10
7
PLS)
*A*C
C: Feedback position (
±
10 V/1
×
10
8
PLS)
*A*C
D: Bus voltage (+8 V / 400 V)
*A: Encoder pulse unit
*B: Outputs 8 V as the maximum torque
*C: Can be used for the absolute position detection system
H0001
BFM
#15074
BFM
#15274
PC11
Analog monitor 1
offset
Set the offset voltage of the analog monitor 1 (MO1) output.
Setting range: -999 to 999 mV
K0
BFM
#15075
BFM
#15275
PC12
Analog monitor 2
offset
Set the offset voltage of the analog monitor 2 (MO2) output.
Setting range: -999 to 999 mV
K0
BFM
#15076
BFM
#15276
PC13
Analog monitor
feedback position
output standard data
Low
(Ver.1.40 or later)
Set the standard position of feedback output with analog monitor 1
(MO1) or 2 (MO2).
Setting range: -9999 to 9999 PLS
K0
BFM
#15077
BFM
#15277
PC14
Analog monitor
feedback position
output standard data
High
(Ver.1.40 or later)
Set the standard position of feedback output with analog monitor 1
(MO1) or 2 (MO2).
Setting range: -9999 to 9999 (
×
10000PLS)
K0
BFM
#15080
BFM
#15280
PC17
Function selection
C-4
Select the home position setting condition in the absolute position
detection system.
0: Need to pass motor Z-phase after power on
1: Not need to pass motor Z-phase after power on
K1
BFM
#15083
BFM
#15283
PC20
Function selection
C-7
(Ver.1.40 or later)
Setting when undervoltage alarm occurs
0: Waveform of power supply voltage is not distorted
1: Set “1” if undervoltage alarm occurs because of distorted power
supply voltage waveform when using power regenerative converter
or power regeneration common converter
H0000
BFM
#15084
BFM
#15284
PC21
Alarm history clear
(Ver.1.40 or later)
Used to clear the alarm history.
0: Disable
1: Enable
H0000
BFM
#15087
BFM
#15287
PC24
Forced stop
deceleration time
constant
(Ver.1.40 or later)
Only the MR-J3-
BS
Set deceleration time constant for forced stop deceleration.
Setting range: 0 to H1FFF
H0000
BFM
#15094
BFM
#15294
PC31
Vertical axis freefall
prevention
compensation
amount
(Ver.1.40 or later)
Only the MR-J3-
BS
Set the compensation amount of the vertical axis freefall prevention
function.
Setting range: HF63C to H09C4 REV
H0000
BFM Number
Servo
Amplifier
Parameter No.
Name
Description
Default
X-axis
Y-axis
Analog monitor 2 (MO2) output selection
0
0
0
Setting when undervoltage alarm occurs
0
0
0
Alarm history clear
0
0
0