7 Before Starting Positioning Operation
64
FX
3U
-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
From the previous page
From the previous page
To the next page
To the next page
Setting the servo series (X-axis), and transferring the servo parameters (X-axis) to the servo
amplifier.
M395
K1
U1\G15000
FNC 12
MOV
Sets the servo series
(X-axis) in unit No. 1.
M391
Ready ON
(X-axis)
SET
M397
Setting the servo series (Y-axis), and transferring the servo parameters (Y-axis) to the servo
amplifier.
M396
K1
U1\G15200
FNC 12
MOV
Sets the servo series
(Y-axis) in unit No. 1.
M391
Ready ON
(Y-axis)
SET
M398
M391
M397
M398
D283.0
D285.0
RST
T12
M390
M398
FNC 40
ZRST
D286
D289
FNC 40
ZRST
SET
M510
FNC 02
SRET
Initializing parameters (BFM), and saves them to flash memory.
Executing system reset after a successful save.
P1
D280.0
D290.1
READY/
BUSY (X-
axis)
SET
M382
Parameter
updating
(X-axis)
M380
D281.0
D291.1
READY/
BUSY (Y-
axis)
SET
M381
Parameter
updating
(Y-axis)
D280.5
Error occurrence (X-axis)
M380
D281.5
Error occurrence (Y-axis)
M380
U1\G72
D290
FNC 12
MOV
U1\G172
D291
FNC 12
MOV
Reads the servo status 2
(X-axis) in unit No. 1.
Reads the servo status 2
(Y-axis) in unit No. 1.