8 Manual Control
8.3 Manual pulse generator operation
147
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
• The manual pulse generator inputs two-phase pulses (A-/B-phase) at 1 edge count.
- Only a differential output type manual pulse generator is connectable.
- Operation from the manual pulse generator is always counted.
The “current MPG input value” is applicable to monitor the pulses from the MPG when the operation is
not in MPG mode.
• The operation speed is proportional to the frequency of pulse strings from the manual pulse generator
according to the manual pulse input magnification.
In addition, the override setting is invalid.
- The following equation provides output pulses to 20SSC-H.
- If the pulse generator magnification is smaller than 1/1, one pulse is output for every multiple input
pulse.
Therefore, the frequency of output pulses is low while the pulse quantity is small.
If the manual pulse input magnification is larger than 1/1, multiple pulses are output for each input pulse.
Therefore, the frequency of output pulses is high while the pulse quantity is large.
If the manual pulse input magnification is larger than 1/1, the motor rpm for each input pulse becomes
larger, causing rough positioning accuracy.
ON
OFF
+1
+1
-1
-1
A-phase
B-phase
A-phase
B-phase
2-phase pulses
Frequency within 100kHz
Input pulses
(frequency, pulse quantity)
Manual pulse generator
20SSC-H
Servo
amplifier
AC Servo
motor
Command
(output
pulses)
Manual pulse generator
input magnification
Numerator
Denominator
Output
pulses
Input pulses
(frequency,
pulse quantity)
Input pulses (frequency, pulse quantity)
from manual pulse generator
X
manual pulse input
magnification
Manual pulse input
magnification (numerator)
Manual pulse input
magnification (denominator)