11 Buffer Memory (Parameters & Monitored Data)
11.3 Monitor Data
228
FX
3U
-20SSC-H Positioning Block User's Manual
11.3.8
Current value of operation speed [BFM #11, #10, BFM #111, #110]
The current value of the operation speed is stored.
The value becomes zero under suspension, or in operation with a manual pulse input.
*1.
Refer to the section shown below for details on the user units.
→
Refer to Section 7.10
11.3.9
Current pulses input by manual pulse generator [BFM #13, #12, BFM #113, #112]
The number of input pulses from the manual pulse generator is stored.
Forward rotation increments the current number of pulses, and reverse rotation decrements it.
Magnification settings for the manual input pulses are not reflected in the stored value.
11.3.10 Frequency of pulses input by manual pulse generator
[BFM #15, #14, BFM #115, #114]
Manual pulse generator input frequency is stored.
POINT
Magnification settings for the manual input pulses are not reflected on the stored value.
11.3.11 Table numbers in execution [BFM #16, BFM #116]
While performing a table operation, the table number in execution is stored.
11.3.12 Version information [BFM #17]
The version of 20SSC-H is stored.
BFM Number
Description
Value Format
Default
X-axis
Y-axis
BFM #11,#10
BFM
#111,#110
0 to 2,147,483,647 (user unit)
*1
Decimal
-
BFM Number
Description
Value Format
Default
X-axis
Y-axis
BFM #13,#12
BFM
#113,#112
-2,147,483,648 to 2,147,483,647 PLS
Decimal
-
BFM Number
Description
Value Format
Default
X-axis
Y-axis
BFM #15,#14
BFM
#115,#114
-100,000 to 100,000 Hz
Decimal
-
BFM Number
Description
Value Format
Default
X-axis
Y-axis
BFM #16
BFM #116
-1
: Not in execution
0-299 : Stores table number in execution
Decimal
-
BFM Number
Description
Value Format
Default
X-axis
Y-axis
BFM #17
-
Ver.1.00 is stored as K100.
Decimal
-