7.11 Cautions for Positioning Operation
3) When the version is Ver.1.30 or later "interrupt 1-speed constant quantity feed (constant position stop
mode) shortest allowable stop" is enabled. (Refer to Fig. B.)
If the system cannot stop at the target position (target address 1) with the setting value of deceleration
time, it stops at the target position (target address 1) using a deceleration time
*1
set by the 20-SSC-H
automatically. (Refer to Fig. B.)
However, if the travel distance to the target position (target address 1) after the interrupt input (INT0)
turns ON is shorter than the travel distance required for a sudden stop, the system passes the 1st target
position (target address 1), decelerates, and then stops at the 2nd target position (target address 1).
(Refer to Fig. C.)
→
For sudden stop, refer to Section 7.5
*1.
Deceleration time setting value is automatically set between sudden stop deceleration time and
deceleration time.
*2.
Set approximate S-shaped acceleration/deceleration or trapezoidal acceleration/deceleration in
"acceleration/deceleration mode."
BFM Number
Data type
X-axis
Y-axis
Target address 1
BFM #501,#500
BFM #601,#600
Control data
Operation speed 1
BFM #503,#502
BFM #603,#602
Control data
Acceleration/deceleration
time change command
(Ver.1.30 or later)
Operation command 2
BFM #519 b5
BFM #619 b5
Control data
Mode selection for the
Interrupt 1-speed
constant quantity feed
Operation command 2
BFM #519 b6
BFM #619 b6
Control data
Interrupt 1-speed
Constant Quantity Feed
(Constant position stop
mode) shortest allowable
stop (Ver.1.30 or later)
Operation command 2
BFM #519 b7
BFM #619 b7
Control data
X-INT0 (input terminal)
-
-
Input terminal
Y-INT0 (input terminal)
-
-
Input terminal
Maximum speed
BFM #14009,#14008
BFM #14209,#14208
Positioning parameters
Acceleration time
BFM #14018
BFM #14218
Positioning parameters
Deceleration time
BFM #14020
BFM #14220
Positioning parameters
Acceleration/deceleration
mode
*2
Operation parameter 1 BFM #14000 b11
BFM #14200 b11
Positioning parameters
Ring counter setting
(Ver.1.10 or later)
Operation parameter 2 BFM #14002 b3
BFM #14202 b3
Positioning parameters
Sudden stop deceleration time (Ver.1.20 or later)
BFM #14102
BFM #14302
Positioning parameters
Acceleration time 2 (Ver.1.30 or later)
BFM #14108
BFM #14308
Positioning parameters
Deceleration time 2 (Ver.1.30 or later)
BFM #14110
BFM #14310
Positioning parameters
Target address 1
Figure B
Start
Interrupt input (INT0)=ON
Travel distance
required for
sudden stop
Travel distance
required for
deceleration stop
Target address 1
Figure C
Start
Interrupt input (INT0)=ON
Travel distance
required for
deceleration stop
Travel distance
required for
sudden stop