7.1 Note on Setting Parameters
From the previous page
From the previous page
To the next page
To the next page
U1\G519
D286
FNC 12
MOV
Reads the operation
command 2 (X-axis) in
unit No. 1.
Sets (writes) the operation
command 2 (X-axis) in
unit No. 1.
D286
U1\G519
FNC 12
MOV
M382
SET
D286.B
Sets the servo parameter
update stop command
(X-axis) in unit No. 1.
U1\G619
D287
FNC 12
MOV
Reads the operation
command 2 (Y-axis) in
unit No. 1.
Sets (writes) the operation
command 2 (Y-axis) in
unit No. 1.
D287
U1\G619
FNC 12
MOV
M381
SET
D287.B
Sets the servo parameter
update stop command
(Y-axis) in unit No. 1.
M382
Enables the control
commands in unit No. 1.
Sets to ON these
commands to initialize each
parameter and to save them
to the flash memory in unit
No. 1.
M383
M381
K5220
U1\G522
FNC 12
MOV
H6363
U1\G523
FNC 12
MOV
SET
M383
When T13 turns ON,
initializing each parameter
of buffer memory, and
saving them (X-axis and
Y-axis) to the flash memory
in unit No. 1 is completed.
It takes 20ms or more for
initailzation of parameters.
T13
K41
T13
Enables control commands
in unit No. 1.
Reads the operation
command 2 (X-axis) in
unit No. 1.
Sets to ON the system
reset command in unit
No. 1.
K5220
U1\G522
FNC 12
MOV
SET
D286.1
D286
U1\G519
FNC 12
MOV
Sets (writes) the operation
command 2 (X-axis) in
unit No. 1.
U1\G519
D286
FNC 12
MOV
SET
M384
M384
When the system reset
command remains ON for
100 ms or more and then
turns OFF, system reset is
executed.
T14
K2
It takes 4 s or more for
saving parameters.