7 Before Starting Positioning Operation
90
FX
3U
-20SSC-H Positioning Block User's Manual
7.5 Sudden stop selection (Ver.1.20 or later)
2) When the STOP command or rotation limit switch turns ON during deceleration stop, the servo motor
suddenly stops in accordance with the sudden stop deceleration time (sudden stop interpolation time
constant).
BFM Number
Data type
X-axis
Y-axis
STOP command
Operation command 1
BFM #518 b1
BFM #618 b1
Control data
Forward rotation
limit (LSF)
Operation command 1
BFM #518 b2
BFM #618 b2
Control data
Reverse rotation
limit (LSR)
Operation command 1
BFM #518 b3
BFM #618 b3
Control data
FLS terminal input
Servo terminal information
BFM #8 b0
BFM #108 b0
Monitor data
RLS terminal input Servo terminal information
BFM #8 b1
BFM #108 b1
Monitor data
Maximum speed
BFM #14009,#14008
BFM #14209,#14208
Positioning parameters
Operation speed
Operation speed 1
BFM #503,#502
BFM #603,#602
Control data
Operation speed 2
BFM #507,#506
BFM #607,#606
Control data
JOG speed
BFM #14013,#14012
BFM #14213,#14212
Positioning parameters
Zero return speed (high speed)
BFM #14025,#14024
BFM #14225,#14224
Positioning parameters
Zero return speed (creep)
BFM #14027,#14026
BFM #14227,#14226
Positioning parameters
Acceleration/
deceleration time
change command
(Ver. 1.30 or later)
Operation command 2
BFM #519 b5
BFM #619 b5
Control data
Deceleration time
BFM #14020
BFM #14220
Positioning parameters
Deceleration time 2 (Ver. 1.30 or later)
BFM #14110
BFM #14310
Positioning parameters
Sudden stop deceleration time
BFM #14102
BFM #14302
Positioning parameters
In individual axis operation
Operation speed
Sudden stop
deceleration time
Deceleration time
Time
Real deceleration time
Real sudden stop deceleration time
Maximum speed
Speed
OFF
ON
STOP command