7 Before Starting Positioning Operation
72
FX
3U
-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
From the previous page
From the previous page
M322
U1\G132
D225
FNC 12
MOV
D223
U1\G619
FNC 12
MOV
Reads the status information
2 (Y-axis) in unit No. 1.
Reads the operation
command 2 (Y-axis) in
unit No. 1.
Resets the positioning
parameter enable command
(Y-axis) in unit No. 1.
RST
D223.4
Sets (writes) the operation
command 2 (Y-axis) in
unit No. 1.
RST
M322
D225.0
U1\G619
D223
FNC 12
MOV
Positioning
parameter
change
completion
flag (Y-axis)
(Ver. 1.20
or later)
Setting the positioning parameter enable command to OFF (Y-axis)
* Set this command to OFF after one operation cycle when the version is earlier than 1.20.
M320
M323
M320
M324
FNC 40
ZRST
END
D220
D225
FNC 40
ZRST
M321
SET
M323
M320
M322
SET
M324
M324