10 Table Operation
10.1 Outline of Table Operation
194
FX
3U
-20SSC-H Positioning Block User's Manual
10.1.4
Table operation execution procedure
The following shows the procedure for executing a table operation.
1
Set the operation pattern and table start No. in the control data.
Note
When operating with XY-axis table information, both axes should be set as using table operation
(simultaneous).
If the same operation pattern is not in both axes, the following operation is executed.
1) When table operation (simultaneous) is set to the operation pattern of the X-axis and a different operation
pattern is set to the Y-axis
The operation pattern of the Y-axis is disregarded, and table operation (simultaneous) is executed.
2) When an operation pattern different than table operation (simultaneous) is set to the operation pattern of
the X-axis and table operation (simultaneous) is set to the Y-axis
X-axis: Operates by the operation pattern set in the X-axis.
Y-axis: Does not operate.
Writing table operation data
Write table operation data to buffer memory beforehand, following the procedure below:
• Transfer the table information from the 20SSC-H flash memory to buffer memories (only while power ON)
→
Refer to Chapter 6
• Write (transfer) table data to buffer memories with FX Configurator-FP.
→
For details on operation, refer to the FX Configurator-FP Operation Manual
• Write table information by a sequence program.
→
For an explanation of applied instructions, refer to the Programming Manual
• Change (write) table information by the test function in GX Developer's BFM monitor.
→
For details on operation, refer to the GX Developer Operating Manual
2
Reboot the START command to begin the table operation.
When operating with XY-axis table information, turn the START command of the X-axis from OFF to ON.
3
The 20SSC-H executes table operation in numerical order from the table
operation start No.
The 20SSC-H executes table operation patterns in numerical order until the table No. with END
command is reached in the operation information.
4
The table operation finishes when the table No. with the END command is
executed.
Item
BFM number
Content
X-axis
Y-axis
Operation pattern selection
BFM #520
BFM #620
b9 : Table operation (individual)
Table operation is executed by X-axis table data and Y-axis table data.
b10: Table operation (simultaneous)
Table operation is executed by XY-axis table data.
Table operation start No.
BFM #521
BFM #621
Specify the table No. of the table operation to be executed.
When setting the table operation (simultaneous) in the operation patterns, set
the X-axis table operation start No. only.
Setting range : 0 to 299