1. Changing the jog speed using the operation speed change function
The system does not accept a change of the operation speed when the change command in operation
disabled is ON.
→
For speed change during operation using the operation speed change function,
refer to Subsection 7.6.2
2. Changing the override setting
Use the override setting to change the ratio of the actual operation speed to the JOG speed.
→
For speed change during operation using the override function, refer to Subsection 7.6.1
BFM Number
Data type
X-axis
Y-axis
Forward rotation JOG
Operation command 1
BFM #518 b4
BFM #618 b4
Control data
Reverse rotation JOG
Operation command 1
BFM #518 b5
BFM #618 b5
Control data
Change command in operation
disabled
Operation command 1
BFM #518 b12
BFM #618 b12
Control data
Speed change command in
positioning operation
Operation command 1
BFM #518 b13
BFM #618 b13
Control data
Speed change value
BFM #513,#512
BFM #613,#612
Control data
Operation speed present value
BFM #11,#10
BFM #111,#110
Monitor data
Received target speed (Ver.1.20 or later)
BFM #27,#26
BFM #127,#126
Monitor data
During operation speed change
Status information
BFM #28 b13
BFM #128 b13
Monitor data
JOG speed
BFM #14013,#14012
BFM #14213,#14212
Positioning parameters
BFM Number
Data type
X-axis
Y-axis
Forward rotation JOG
Operation command 1
BFM #518 b4
BFM #618 b4
Control data
Reverse rotation JOG
Operation command 1
BFM #518 b5
BFM #618 b5
Control data
Override setting
BFM #508
BFM #608
Control data
Operation speed present value
BFM #11,#10
BFM #111,#110
Monitor data
JOG speed
BFM #14013,#14012
BFM #14213,#14212
Positioning parameters
Operation speed
Speed change value
During operation
speed change
Speed change command
in positioning operation
10000Hz
0Hz
0Hz
10000Hz
7000Hz
10000Hz
7000Hz
Speed
Time
JOG input
JOG speed (parameter)
ON
OFF
ON
OFF
ON
OFF
7000Hz
10000Hz
100%
70%
10000Hz
7000Hz
ON
OFF
Speed
Time
JOG input
JOG speed