11 Buffer Memory (Parameters & Monitored Data)
11.2 Servo Parameters
221
FX
3U
-20SSC-H Positioning Block User's Manual
11
Buffer
M
e
m
o
ry
12
Pr
ogr
am
Exam
ple
13
D
iagnostics
A
List
of
Par
a
m
e
ter
s and
Da
ta
B
V
e
rs
ion
Infor
m
at
ion
BFM
#15052
BFM
#15252
PB34
Gain changing
Vibration
suppression control
resonance frequency
setting
Set the resonance frequency for vibration suppression control when the
gain changing is valid.
Setting range: 1 to 1000 (
×
0.1 Hz)
K1000
BFM
#15063
BFM
#15263
PB45
Vibration
suppression control
filter 2
(Ver.1.40 or later)
Set the vibration suppression control filter 2 setting frequency selection
and notch depth selection.
• Vibration suppression control filter 2 setting frequency selection
0: Disable
1: 2250 Hz
5F: 4.5 Hz
• Notch depth selection
0: Deep (-40.0db)
F: Shallow (-0.6db)
H0000
BFM Number
Servo
Amplifier
Parameter No.
Name
Description
Default
X-axis
Y-axis
Vibration suppression control filter 2
setting frequency selection
0
Notch depth selection