11.4.11 Operation command 2 [BFM #519, BFM #619]
*1.
Timing of detection
1) Level detection: activated when the bit is set or cleared.
2) Edge detection: activated at OFF-to-ON transition (b1: ON-to-OFF transition).
*2.
BFM #619 b1 is not available.
BFM Number
Bit
Number
Setting Item
Description
Detection
*1
Default
X-axis
Y-axis
BFM
#519
BFM
#619
b0
Remaining travel
cancel command
Set this to cancel the standby status for the remaining travel
after the STOP command.
→
For details on the stop command, refer to Section 7.4
Edge
H0000
b1
*2
System reset
command
(Ver.1.10 or later)
Turns ON for 100ms or more, and resets the 20SSC-H
system when detecting this bit's falling edge.
→
For details of the system reset command,
refer to Subsection 7.9.12
Edge
b2, b3
Not available
-
-
b4
Positioning
parameters
enable command
Set this to enable positioning parameters in the buffer
memories.
Whenever you make a change to positioning parameters, this
bit must be set before starting operation.
Edge
b5
Acceleration/
deceleration time
change
command
(Ver.1.30 or later)
Select the acceleration/deceleration time setting
(except for interpolation operation).
→
For details of changeover of the acceleration/
deceleration time, refer to Section 7.7
OFF: Performs positioning operation using acceleration time
and deceleration time.
ON:
Performs positioning operation using acceleration time
2 and deceleration time 2.
Level
b6
Mode selection
for the Interrupt
1-speed constant
quantity feed
(Ver.1.10 or later)
OFF : Relative positioning by the specified travel distance
ON : Absolute positioning by the specified address
(constant position stop mode)
→
For details on the interrupt 1-speed constant quantity
feed, refer to Section 9.3
Level
b7
Interrupt 1-speed
Constant
Quantity Feed
(Constant
position stop
mode) shortest
allowable stop
(Ver.1.30 or later)
Enables (makes valid) interrupt 1-speed constant quantity
feed (constant position stop mode) shortest allowable stop.
→
For details of the operation, refer to Subsection 9.3.2
OFF: Performs deceleration stop after detecting an interrupt
input.
ON:
Performs deceleration stop using the shortest
deceleration time set by 20SSC-H depending on the
position where an interrupt input is detected.
Level
b8
Servo OFF
command
Set this to turn the servo OFF.
→
For details on the servo ON/OFF state,
refer to Subsection 7.9.5
0: servo ON
1: servo OFF
Level
b9
Servo
parameters
transfer
command
Set this to transfer servo parameters in the buffer memories to
the servo amplifier.
Edge
b10
Gain changing
command
Changes the gain of the amplifier from the 20SSC-H.
For details on changing gain, refer to the manual shown
below.
→
MR-J3-
B Servo Amplifier Instruction Manual
→
MR-J3W-
B Servo Amplifier Instruction Manual
→
MR-J3-
B Safety Servo Amplifier Instruction Manual
Level
b11
Servo parameter
update stop
(Ver.1.10 or later)
Set this to disable update of servo parameters even when the
servo amplifier gives servo parameter update request.
→
For details on the servo parameter update stop
command, refer to Subsection 7.9.13
Level
b12 to b15 Not available
-
-