9 Positioning Control
9.8 Multi-Speed Operation
171
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
9.8
Multi-Speed Operation
The multi-speed operation is a positioning procedure, available only in the table operation.
For details on controlling by table operation, and changing the operation speed, refer to the following sections.
→
For details on the table operation, refer to Chapter 10
→
For details on the operation speed change, refer to Section 7.6
→
For details on the torque limit, refer to Subsection 7.9.3
→
For details on the STOP command, refer to Section 7.4
→
For setting of ring operation in the current address, refer to Section 7.8
1. Operation
1) Set the operation information, speed information, and position (address) information for each table.
- X-, Y-axis table information: Sets Multi-speed operation to Operation information.
- XY-axes table information:
Sets X-axis multi-speed operation or Y-axis multi-speed operation to
Operation information individually.
(Even if performing multi-speed operation using XY-axes table information,
the X-axis and the Y-axis operate independently of each other.)
2) Set "table operation (individual)" or "table operation (simultaneous)" in accordance with the table
information used in "operation pattern selection."
3) Set the table number which specifies multi-speed operation to "table operation start number", and set the
START command from OFF to ON.
The system will start positioning operation for the specified table number. (The positioning completion
signal is set to OFF.)
4) The operation continuously executes the table positioning until the END command. (above figure)
5) The work piece decelerates to stop at the specified position (address) in the table before the END
command. When the operation ends, the positioning completion signal turns ON.
→
For the parameters, control data and monitor data, refer to Chapter 11
→
For details on the table operation, refer to Chapter 10
BFM Number
Data type
X-axis
X-axis
Table information (X-axis)
BFM #1000 to #3999
-
Table information
Table information (Y-axis)
-
BFM #4000 to #6999 Table information
Table information (XY-axis)
BFM #7000 to #12999
Table information
Table operation (individual)
Operation pattern selection BFM #520 b9
BFM #620 b9
Control data
Table operation
(simultaneous)
Operation pattern selection BFM #520 b10
BFM #620 b10
Control data
Table operation start number
BFM #521
BFM #621
Control data
STOP command
Operation command 1
BFM #518 b1
BFM #618 b1
Control data
START command
Operation command 1
BFM #518 b9
BFM #618 b9
Control data
Simultaneous START flag
Operation command 1
BFM #518 b10
Control data
(table No.1)
(table No.2)
(table No.3)
Speed
information
Position
information
Position
information
Position
information
Speed
information
Speed
information
Deceleration
time
Time
Speed
Acceleration
time
START command
Maximum speed
ON
OFF
OFF
ON
Positioning completion
ON