11 Buffer Memory (Parameters & Monitored Data)
11.5 Table Information
248
FX
3U
-20SSC-H Positioning Block User's Manual
1. Position information
Set the following items according to the table operations set in the operation information.
*1.
Refer to the section shown below for details on the user units.
→
Refer to Section 7.10
*2.
The setting range is 0 to 3,276 (
×
10 ms) if the version is earlier than Ver. 1.40.
2. Speed data (fx, f, fy)
Sets the operation speed of the positioning operation to be used for table operation.
Setting range: 1 to 2,147,483,647 [User unit]*
1
Set the value within 1 to 50,000,000 Hz in converted pulse data.
*1.
Refer to the section shown below for details on the user units.
→
Refer to Section 7.10
3. Circular information (i, r, j)
Sets center coordinate and radius for a circular line to be used in circular interpolation operation.
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
*1
Set the value within -2,147,483,648 to 2,147,483,647PLS in the converted pulse data.
*1.
Refer to the section shown below for details on the user units.
→
Refer to Section 7.10
299
BFM
#3991,#3990
-
BFM
#12981,#12980
Position
informa-
tion
Position information x
Same as the table 0
K-1
-
BFM
#6991,#6990
BFM
#12983,#12982
Position information y
K-1
BFM
#3993,#3992
-
BFM
#12985,#12984
Speed
informa-
tion
Speed information x
K-1
-
BFM
#6993,#6992
BFM
#12987,#12986
Speed information y
K-1
-
-
BFM
#12989,#12988
Circular
informa-
tion
Center coordinate i
Radius r
K-1
-
-
BFM
#12991,#12990
Center coordinate j
K-1
BFM #3994
BFM #6994
BFM #12992
Operation information
K-1
BFM #3995
BFM #6995
BFM #12993
m code information
K-1
Table Operation
Action
Item
Description
Positioning operation
Set the target address.
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
*1
Set the value within -2,147,483,648 to 2,147,483,647PLS in the converted
pulse data.
Changes the current
address
Specify the current address
(user) after changed.
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
*1
Set the value within -2,147,483,648 to 2,147,483,647PLS in the converted
pulse data.
Dwell
Set wait time to be spent for
shifting operations.
Setting range: 0 to 32,767 (
×
10 ms)
*2
Jump
Sets the table number of the
jump address.
Setting range: 0 to 299
Table No.
BFM Number
Name
Description
Default
X-axis
Y-axis
XY axes