7 Before Starting Positioning Operation
128
FX
3U
-20SSC-H Positioning Block User's Manual
7.11 Cautions for Positioning Operation
4. 2-speed positioning operation
1) If the travel distance at the first speed is small
If the travel time is smaller than the time
*1
needed to decelerate to the operation speed 2, the first
operation speed does not reach the operation speed 1.
If the travel distance of the first speed is zero, the travel is at the second operation speed and travel
distance. (No error is caused.)
*1.
For the relation between the time for the actual deceleration and the specified time for desired
deceleration, refer to the following.
→
Refer to Section 7.2
*2.
Set approximate S-shaped acceleration/deceleration or trapezoidal acceleration/deceleration in
"acceleration/deceleration mode."
BFM Number
Data type
X-axis
Y-axis
Travel distance
Target address 1
BFM #501,#500
BFM #601,#600
Control data
Target address 2
BFM #505,#504
BFM #605,#604
Control data
Operation speed setting
Operation speed 1
BFM #503,#502
BFM #603,#602
Control data
Operation speed 2
BFM #507,#506
BFM #607,#606
Control data
Acceleration/deceleration
time change command
(Ver.1.30 or later)
Operation command 2
BFM #519 b5
BFM #619 b5
Control data
Maximum speed
BFM #14009,#14008
BFM #14209,#14208
Positioning parameters
Acceleration time
BFM #14018
BFM #14218
Positioning parameters
Deceleration time
BFM #14020
BFM #14220
Positioning parameters
Acceleration/deceleration
mode
*2
Operation parameter 1 BFM #14000 b11
BFM #14200 b11
Positioning parameters
Acceleration time 2 (Ver.1.30 or Later)
BFM #14108
BFM #14308
Positioning parameters
Deceleration time 2 (Ver.1.30 or later)
BFM #14110
BFM #14310
Positioning parameters
Speed
Desired
acceleration
time
Desired
decceleration
time
Approximate
S-shaped
control
Trapezoidal control
Operation
speed 1
Operation
speed 2
Time
Start
Travel time < desired deceleration time
*1
*1
*1