7 Before Starting Positioning Operation
47
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
7.1 Note on Setting Parameters
5
Transferring positioning parameters and servo parameters to the 20SSC-H
(Writing them to the flash memory)
Select [Online]
[Write to module].
When the Write to module dialog box appears, select data to be written, and then click the [OK]
button.
Make sure to check the check box "Flash ROM write" here because parameters should be written
also to the flash memory in the 20SSC-H.
Saving parameters to the flash memory
Make sure to save the parameters to the flash memory.
When the power of the 20SSC-H is turned OFF once and then turned ON again, the following data stored in
the flash memory is transferred to the buffer memory.
6
Transferring servo parameters to the servo amplifier
1) Turn OFF the power of the servo amplifier and PLC (including the 20SSC-H).
2) Turn ON the power of the servo amplifier.
3) Turn ON the power of the PLC (including the 20SSC-H).
Transfer method by system reset (20SSC-H Ver. 1.10 or later)
By system reset performed for the 20SSC-H Ver. 1.10 or later from FX Configurator-FP (Ver. 1.10 or later),
servo parameters will be transferred to the servo amplifier.
1) Select [Online]
[System reset].
2) When the following message appears, click the [Yes] button to perform system reset.
Click the [No] button to cancel the system reset operation.
BFM number
Positioning parameters
X-axis
BFM #14000 to #14199
Y-axis
BFM #14200 to #14399
Servo parameters
X-axis
BFM #15000 to #15199
Y-axis
BFM #15200 to #15399
Table information
X-axis
BFM #1000 to #3999
Y-axis
BFM #4000 to #6999
XY-axis